Temperature-Pressure
Relief Valve
_WARNING
At the time of manufacturethis water heater was provided
with a combination temperature.pressures raliofvalvecertified
by a nationallyrecognized testing laboratorythat maintains
.p_'odic inspection of production of listedequipmentor mete-
rmals, a s meeting the requirements for Relief Valves and
AutomaticGasShutoff D evices for Hot Water Supply Systems,
and the latest edition of ANSI Z21.22 and the code require-
!mentsof ASME. If replaced,the valvemust meet the require-
menu ofIoealcodes,but not lessthana combination tempera-
ture and pressure relief valvecertifiedas meetingthe require-
mentsfor ReliefValvesand AutomaticGasShutoff Devices for
Hot Water Supply Systems, ANSI Z21.22bya nationally recog-
nizad testing laboratorythat mmntains periodicinspection of
production of listedequipment or materials.
The valvemust he markedwith a maximum sat pressure loot
to exceedthe marked hydrostaticworking pressureof the
water heater(IS0 II_J_, in.) and a discharge c apacity not less
thanthe water heater inputrate asshown on the modelrating
plate. (Electric heaters• watts dividedby 1000x 3415 equal
BTU/Hr.rate.)
Yourlocaljurisdictional anthori_, whilemandating the useofa
temperature-pressure relief valvecomplying with ANSI Z21.22
and ASME, may require a valvemodeldifferentfrom the one
fomishedwith the wakerheater.
Compliance with suchlocalrequirements mustbe satisfied by
the installeror end userof the water heaterwith a locally pre-
scribed temperature-pressure relief valveinstalled in the desig.
nated opening in the water heater in placeof the factory fur-
nisbedvalve,
Forsafe operationofthe water heater,the reliefvalvemustnot
beremovedfrom it_ designated o pening or plugged,
IThe temperature-pressure reliefvalvemustbe installed directly
intothefittingofthewaterheaterdesignated for the reliefvalve.
Position tile valvedownward end provide tubingsothat anydis-
chargewill exit onlywithin 6 inches above,or at any distance
belowthe structuralfloor.Be certainthat no contact ismade
with anyliveelectrical p art. The discharge o pening mustnot be
blocked or reducedin size underanycircumstances. Excessive
length,over30 feet,or useof more than fourelbows cancause
restflcdon andreducethedischarge c apacity ofthe valve.
No valveor otherobstruction isto he placed between the relief
valveand the tank. Do not connect t ubingdirectly to discharge
drainunless a 6" air gapisprovided. Toprevent b odily injury, h ez.
ard to life,or propertydamagethe reliefvalvemustbe allowed
to discharge water in quantities should c_rcumstances demand. I f I
the discharge p ipeisnot connectedto a drainor othersuitable
means, t he waterRow maycause property damage,
The Discharge Pipe:
• Mustnot be smallerin sizethan the outlet pipesize of the
valve,or haveanyreducing couplings o r otherrestrictions.
• Mustnet be plugged or blocked.
• Mustbe ofmateriallistedfor hot water distribution.
I. Must be installedso as to allowcompletedrainageof both
the temperature.pressurerelief valve, and the discharge
pipe.
• Mustterminateat an adequate drain.
• Mustnot haveanyvalvebetweenthe reliefvalveand tank.
AWARNING
The temperature-pressure relief valve must be manually
operated at least once a yea_ Caution shouldbe taken to
ensurethat (I) no one is in front of or aroundthe outlet of
the temperature-pressure relief valvedischarge line, and (2)
the water manually dischargedwill not causeany bodily
injury or property damage because the water may be
extremely hot.
If after manuallyoperating the valve, it failsto completely
resetand continuesto releasewater,immediatelydose the
cold water inlet to the water heater, follow the draining
instructions,and replace the temperature-pressure relief
valvewith a newone.
HOT
[]
SHUTOFF
COLD
VALVE
"EHPERATURE-
PRESSURE
RELIEF VALVE
(Do not cap or plus)
6" AIR GAP
RELIEFVALVEOPENING
At the time of _ocu_,
this water heater was provided with a combinationtem-
perature-pressurerelief valvelisted ascomNyfeg with the standa_l for rdiet" valvesand
automatic gas shut-off devices for hot war_r supply systems,ANSi Z21.22. For safe
operation of the water heater,the _lef valvemust not be removed from its designated
ypOouint
of instaibtion cr plugged.
r load urisdictiona{ authori_, while mandating the use of a tem_rature-pre_sure
re{ief valvecomplyingwith ANSI 7-.21,22andASPIE,may require a _alve model dfferent
from the one furnishedwith the water heater
Compliancewith suchlocal requirements must be satisfied by the ins_ler or end user
of the water heater with a locallyprescril_ temperature-pressure relief valveinstalled
in the designated openingin the water heater
See manual heading-'q'ernperature-FYessure R elief Valves"for instalbtion and mainte-
nance of relief valve,discharge line, and other safer 7 precautions.