3 7 63 1515 0
1. Port Description of Microprocessor
Port No.
Port Name
1
P60
2
P61
3
P62
4
P63
5~12
P50~P57
13~16
P20~P23
17
VDD
18
PB0
19
VSS
20
XI,PB1
21
XO
22
VDD
23
OSCI
24
OSCO
25
MODE
26
MCLK
27
MDATA
28
MLD
29
DSPRST
30
IPFLAG
31,32
PCON4,3
33
PCON2
34
AVDD
TE
L 13942296513
35
PCON1
36
AMUTE
37
HPMUTE
38
RWSEL
39
STAT
40
ACDET
41
BBST
42
HOLD
43
VREF-
44
LBATT
45
VOLUME
46
P46
47
P47,WDOUT
48
LEDDRV
49
ELDDRV
50
CHG
51
LCDSD
52
LCDRMC
53
PB5
54
VREF+
55,56
PB6,7
57
MP3 MLD
58
MP3 RESET
59
DATA STOP
www
60
P93
61
AVSS
62,63
KEY1, 2
.
64
KEYEXT
65
RCHDET
66
VDD

CIRCUIT DESCRIPTION

I/O
O
DSP (IC3) reset output.
-
Unused.
O
DSP (IC3) power down control.
-
Unused.
-
Unused.
-
Unused.
-
+3.0v power supply.
-
Unused.
-
GND
-
Unused.
-
Unused.
-
+3.0v power supply.
I
Crystal oscillation circuit input.
O
Crystal oscillation circuit output.
-
Connected to VDD.
O
DSP (IC15) command clock signal output.
O
DSP (IC15) data signal output.
O
DSP (IC15) command load signal output.
O
DSP (IC15) reset signal output.
I
Unused.
-
Unused.
O
RF AMP power down control.
-
+3.0v analog power supply.
O
System power supply control.
O
Audio mute control.
O
Headphones mute control.
O
RF gain control.
I
Status signal input from DSP (IC15).
I
Detection port of AC adaptor.
O
Control port of bass boost.
I
Input port of hold switch.
-
GND
I
Battery level detection port.
I
Input port of volume.
O
Crystal oscillation circuit is stopped when in stop mode(Hi).
-
Unused.
-
Unused.
-
Unused.
O
Rechargeable active output. Batt. charge ON : H
O
Serial data output for LCD.
-
Unused.
-
Unused.
-
+3.0v power supply.
-
Unused.
O
Command load output for MP3.
O
Reset output for MP3.
O
Data signal output for MP3.
-
Unused.
x
ao
u163
y
-
GND
I
Key signal input.
i
I
Remote control signal input.
Detection port for low rechargeable battery.
I
Detected : more than 0.2V
-
+3.0v power supply.
DPC-MP727/MP922
2 9
8
Function
Q Q
3
6 7
1 3
1 5
co
.
9 4
2 8
ACTIVE
H
ON
OFF
0 5
8
2 9
9 4
2 8
ON
ON
DETECTED
OFF
OFF
m
9 9
L
9 9
ON
ON
ON
3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Dpc-mp922