Summary of Contents for Kenmore 580.72053

  • Page 1 Owner's Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR Model, Modelo 580.72053 Sears, Roebuck and Co., Hoffman www.sears.com ® DE AIRE DE VENTANA Estates, IL 60__'3J.S."A.
  • Page 2: Table Of Contents

    (consisting of refrigerant, connecting tubing, and compressor), if defective in material or workmanship. Features ... Using the Air Conditioner ... 9 Air Conditioner MAINTENANCE Air Filter Cleaning ..4 Air Conditioner Cleaning ... 11 How to Remove the Front Grille ... 11 How to Replace the Front Grille ...
  • Page 3: Safety

    IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 4: Electrical Requirements

    OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVETHEPOWERSUPPLYCORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED THIS APPLIANCE. A 115-volt 60 Hz, AC only, 15A fused and properly grounded electrical supply is required. A time delay fuse or time delay circuit breaker is recommended.
  • Page 5: Installation

    • Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. • Make sure air conditioner does not fall during installation. REQUIRED TOOLS: • Tight Fitting gloves •...
  • Page 6: Installation

    Windows used for installation must be strong enough to support the weight of the air conditioner. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.
  • Page 7: Removal From Window

    INSTALL THE AIR CONDITIONER WINDOW • Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L brackets. • When the air conditioner drops into the L brackets, the air conditioner will be centered in window opening as shown in FIG.
  • Page 8: Operation

    SOUNDS FIG.11 Aside from the regular fan motor and compressor sounds coming from your air conditioner, you will once in a while hear a pinging sound. This is the result of moisture being picked up from the air in the room and thrown against the air conditioner's This is normal and should not be cause for concern.
  • Page 9: Features

    1. Plug in the air conditioner. hazards, do not use an extension cord or an adapter plug.) 2. Set the TEMP control to the coolest setting. 3. Set the MODE control at the highest COOL level.
  • Page 10: Air Conditioner Features

    TEMP knob to the desired position. The 5 or 6 position is a normal setting for average conditions. MODE OFF : Turns the air conditioner HIGH FAN : High fan speed operation without cooling. LOW FAN : Low fan speed operation without cooling.
  • Page 11: Maintenance

    • Wash the Air Filter under the faucet with warm water. Be sure to shake off all the water before replacing the filter. AIR CONDITIONER CLEANING Clean the front grille and inlet grille by wiping with a cloth dampened in a mild detergent solution.
  • Page 12: Troubleshooting

    TEMP Controlset too warm. Frontof unit isblockedby drapes,blinds,furniture, etc.Air dis_bution is restricted. Doors,windows,re_]isters, etc. open.Coldair escapes. Unitrecentlyturnedon in hot room. THE AIR CONDITIONER TURNS ON AND OFF RAPIDLY. Check if... I Outsidetemperatoreisextremelyhot. NOISE WHEN UNIT IS COOLING. Check if... Sound offanhitting water - moisture r emoval system.
  • Page 14: Repair Parts

    Room Air Conditioner To order Parts call Toll Free Model No. 580.72053100 1-800-4-MY-HOME®(1-800-469-4663) CAUTION: Use the Kenmore part number on all orders, not the illustration number. CABINET & FRONT GRILLE ASS'Y 11/00 - 14 -...
  • Page 15 CAUTION: Use the Kenmore part number on all orders, no..._t the illustration CABINET POS. NO 1 - A 2 - A 3 - A 4 - A 5 - A 6 - A 7 - A 8 - A 9 - A...
  • Page 16 CAUTION: Use the Kenmore part number on all orders, not the illustration F-B- 11/00 580.72053100 CONTROL BOX ASS'Y 11-B - 16 - number. IO-B...
  • Page 17 CAUTION: Use the Kenmore part number on all orders, not the illustration POS. NO PART NO 1 - B 2 - B 4H01254A 3 - B 4 - B 5 - B 6- B 7 - B 8 - B...
  • Page 18 580.72053100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. AIR HANDLING & CYCLE PARTS 10-C 11/00 - 18 -...
  • Page 19 CAUTION: Use the Kenmore part number on all orders, not the illustration number. AIR HANDLING POS. NO 1 -C 3- C 4- C 5- C 6- C 7- C 8- C 9- C 10-C 11- C # = Functional Parts...
  • Page 20 580.72053100 CAUTION: Use the Kenmore part number on all orders, no___tt the illustration number. COMPRESSOR PARTS 10-D 11/00 - 20 -...
  • Page 21 CAUTION: Use the Kenmore part number on all orders, not the illustration POS. NO PART NO 4H00947A 2- D 4H01058A 3- D 3550U-L004A 4- D 6750U-L050A 5- D 4986U-L001G 6 - D 2520UABC2EA 7- D 1NHA0801206 8- D 4810AR4155B 9- D...
  • Page 22 580.72053100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. INSTALLATION KIT ASS'Y 1-5-- 11/00 - 22 -...
  • Page 23 CAUTION: Use the Kenmore part number on all orders, not the illustration INSTALLATION POS. NO PART NO 1- E 3211AR3239B 3211AR3239A 4810A30113A 4- E 1TTG0402618 # = Functional Parts * = Non-Illustrated Parts 580.72053100 KIT ASS'Y DESCRIPTION GUIDE PANEL, LEFT...