10/25/04 1:34 PM
Fixing the Installation Plate
Before fixing the installation plate to the wall or window frame, you
must determine the position of the 65-mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
◆ Right
◆ Left
◆ Underside (right)
◆ Rear
1
Determine the position of the pipe and drain hose hole as seen in the
picture and drill the hole with an inner diameter of 65mm so that it
slants slightly downwards.
2
If you fix the indoor unit to a...
Wall
Window frame
3
Fix the installation plate to the wall giving attention to the weight of the
indoor unit.
➢ If you mount the plate on the concrete wall with anchor bolts,
the anchor bolts must not be projected by more than 20mm.
4
Determine the positions of the wooden uprights to be attached to the
window frame.
5
Attach the wooden uprights to the window frame giving attention to the
weight of the indoor unit.
6
Attach the installation plate to the wooden uprights using tapping
screws as seen in the picture.

Purging the Indoor Unit

On delivery, there may be inert gas inside the indoor unit.
You should purge the gas from the indoor unit before connecting
the assembly pipe.
Unscrew the caps at the end of each pipe.
Result: All inert gas exhausts from the indoor unit.
To prevent dirt or foreign substance from getting into the
pipes during installation, do NOT remove the caps completely
until you are ready to connect the pipes.
Page 7