Error
Problem
codes
050B
When the temperature of the
center thermistor of the fuser unit
is lower than the idle
temperature, the side thermistor
of the fuser unit detected a
temperature higher than the
specified value.
050C
When the temperature of the
center thermistor of the fuser unit
is higher than the idle
temperature, the side thermistor
of the fuser unit detected a
temperature lower than the
specified value.
050D
---
050F
---
0700
---
0800
Error occurred in the internal
temperature sensor.
0900
Machine detected that supplied
power was unstable.
0A01
---
0A02
The main fan failure was
detected.
0B01
Error in the high-voltage power
supply PCB ASSY while the
machine is in operation.
0B02
Error in the high-voltage power
supply PCB ASSY in the ready
state.
0C00
Error occurred in the density
sensor.
0D01
---
0D02
---
0D03
---
0D04
---
0E00
---
Refer
Error
to:
codes
2-36
1001
---
1002
---
1003
The registration mark L PCB is
dirty and cannot normally receive
reflected light.
2-36
1004
The registration mark R PCB is
dirty and cannot normally receive
reflected light.
1100
---
1300
---
1400
---
1C00
---
1D01
Communication error occurred in
the LED ASSY (Black).
2-37
1D02
Communication error occurred in
the LED ASSY (Yellow).
2-37
1D03
Communication error occurred in
the LED ASSY (Magenta).
2-38
1D04
Communication error occurred in
the LED ASSY (Cyan).
2-38
1E01
Access is unavailable between
the main PCB and LED control
PCB.
2-38
1E02
Read/Write is unavailable
between the main PCB and LED
control PCB.
2-39
2001
---
2002
---
2003
---
2004
---
2005
---
2006
---
2101
---
2-13
Problem
Confidential
Refer
to:
2-39
2-39
2-40
2-40
2-40
2-40
2-41
2-41