4.27 Setting of the parameter unit and operation panel

Purpose
Switch the display language of the
parameter unit
Use the setting dial of the operation
panel like a potentiometer for
frequency setting.
Key lock of operation panel
Control of the parameter unit,
operation panel buzzer
Adjust the LCD contrast of the
parameter unit

4.27.1 PU display language selection (Pr. 145)

You can switch the display language of the parameter unit (FR-PU04/FR-PU07) to another.
Parameter
Name
Number
145
PU display language selection

4.27.2 Setting dial potentiometer mode/key lock selection (Pr. 161)

The setting dial of the operation panel (FR-DU07) can be used like a potentiometer to perform operation.
The key operation of the operation panel can be disabled.
Parameter
Name
Number
Frequency setting/key lock
161
operation selection
Parameter that must be Set
PU display language selection
Operation panel operation selection
PU buzzer control
PU contrast adjustment
Initial Value
0
Setting
Initial Value
Range
0
1
0
10
11
Setting of the parameter unit and
Pr. 145
Pr. 161
Pr. 990
Pr. 991
Setting Range
0
1
2
3
4
5
6
7
Description
Setting dial frequency setting mode
Setting dial potentiometer mode
Setting dial frequency setting mode
Setting dial potentiometer mode
operation panel
Refer to Page
393
393
395
395
Description
Japanese
English
Germany
French
Spanish
Italian
Swedish
Finnish
Key lock
invalid
Key lock
valid
393