Configuration Terminal Problems - HP 5800-48G Installation Manual

5820x & 5800 switch series
Hide thumbs Also See for 5800-48G:
Table of Contents

Advertisement

Configuration terminal problems

If the configuration environment setup is correct, the configuration terminal displays booting information
when the switch is powered on. If the setup is incorrect, the configuration terminal displays nothing or
garbled text.
No terminal display
If the configuration terminal displays nothing when the switch is powered on, verify the following items:
The power supply is supplying power to the switch.
The console cable is correctly connected.
The console cable has no problem and the terminal settings are correct.
Garbled terminal display
If terminal display is garbled, verify that the following settings are configured for the terminal, for
example, HyperTerminal:
Baud rate—9,600
Data bits—8
Parity—none
Stop bits—1
Flow control—none
Emulation—VT100
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents