2-4 Other Settings Using the "VN-C205U Setup Tool" (4. Alarm Setting) (Continued)
Alarm Input
Item
1
Alarm 1/Alarm 2
This section describes setting procedures for alarm input.
Mode
For selecting whether to enable or disable the input signals.
Set Values : Available, Not Available
Detect Mode
For selecting the method for detecting input signals.
Make
: Detect input signals at the "Make" contact point.
Break
: Detect input signals during "Break".
Toggle : Detect input signals at both "Make" and "Break".
Alarm Output
For selecting whether to output from the alarm output terminal
when there is alarm input.
Not Available : Do not output from the alarm output terminal.
Alarm Output 1 : Send output from the Alarm Output 1 terminal.
Alarm Output 2 : Send output from the Alarm Output 2 terminal.
Note
Unless the alarm output in the "Alarm Output" tab is enabled,
this function will not be activated even if alarm output is
selected in the alarm input settings. (
Message Packet
For setting whether to send alarm packets to the PC when there
is alarm input.
Not Available : Do not send alarm packets.
Available
: Send alarm packets.
Alarm FTP
For operation according to the [Alarm FTP] in the FTP Client
feature when there is alarm input. Please refer to FTP Client
Settings (
Page 50) for details on alarm FTP.
Set Values: Available, Not Available
Shutdown
Set to "Available" to quit all operations upon alarm input. Using
this Shutdown function enables operations of this camera to
end safely even during recording into CF cards.
Not Available : Do not shut down.
Available
: Shut down.
Note
• When this is set to "Available", all alarm input except alarm
output and message packets will be disabled.
42
Function/Set Value
Page 44)
Initial Value
Item
2
Relay Alarm
Not Available
Make
Not Available
• Alarm Output
• Message Packet
• Alarm FTP
• Shutdown
Not Available
Not Available
3
Retry (1 to 3)
Not Available
4
List
Function/Set Value
Set here to enable the relay alarm function, which is activated
when 2 alarms are received within a preset time interval.
The sequence and time interval for the alarm input can be specified.
When [Alarm Output] is selected, alarm signal output will be
sent to the alarm output terminal on the ceiling mount accord-
ing to the output port settings.
Notes
• A second alarm input enables this relay alarm function,
and alarm will not be activated for this second input.
• Unless the alarm output in the "Alarm Output" tab is
enabled, this function will not be activated even if alarm
output is selected in the alarm input settings. (
* Please refer to the [Alarm 1/2] item for details on the set val-
ues.
For setting the no. of times alarm notification is to be sent to
the "V.Networks Controller". (Set Value: 1 to 3)
Note
• Alarm notification may fail, depending on the LAN
environment in use. If it fails, set the value for alarm
notification to "3". In this case, alarm by the "V.Networks
Controller" itself is set off only once.
Press here to display the IP address of the PCs to which an
alarm notification is sent. ("Distribution Address List" Screen)
To delete a distribution address, select the IP address to de-
lete, followed by pressing the Delete button.
Notes
• The list allows setting of up to 10 addresses.
• Message packets will not be sent out when there are 11 or
more addresses.
Initial Value
Not Available
Page 44)
*Please
refer to
the [Alarm
1/2] item
for the
initial
values.
1
43