Removing The Sensors - Epson Stylus Photo 1390 Service Manual

Color inkjet printer
Hide thumbs Also See for Stylus Photo 1390:
Table of Contents

Advertisement

EPSON Stylus Photo 1390/1400/1410

4.2.8 Removing the Sensors

4.2.8.1 PE Sensor Holder
1.
Remove the ASF Assy. See Section 4.2.4 on page 86.
2.
Remove the PE Sensor Connector Cable from the five tabs on the Release Holder
Assy and the two tabs on the Head Cable Cover.
Head Cable Cover
Release Holder Assy
Figure 4-137. Releasing the Cables
3.
Release the tabs that secure the PE Sensor Holder from the cutout of the Main
Frame with a flat-blade screwdriver, then slide it upwards then toward you to
remove it.
Front
Tab
Figure 4-138. Removing the PE Sensor Holder
DISASSEMBLY AND ASSEMBLY
Tabs
PE Sensor Connector Cable
Tabs
PE Sensor Holder
Disassembly/Assembly Procedures
Align the four tabs and Guide Pin on the PE Sensor Holder with the
positioning holes on the Main Frame correctly so that there is no
gap between the PE Sensor Holder and the Main Frame.
Figure 4-139. Installing the PE Sensor
Revision B
Tabs
Guide pin
124