DIP SWITCHES

* - Default factory setting
Block 1, DIP Switch 1 – Auto Close
ON – Auto close feature enabled
OFF* – Auto close feature disabled
NOTE: To adjust auto close time refer to figure 17.
Block 1, DIP Switch 2 – Audible Motion Alarm
ON – Audible motion alarm enabled
OFF* – Audible motion alarm disabled
Block 1, DIP Switch 3 – Extended Soft Start/Stop
ON – Extended soft start/stop operation enabled
OFF* – Normal soft start/stop operation
Block 1, DIP Switch 4 – Time of Soft Start/Stop
ON – Max. extended time of soft start/stop operation
OFF* – Extended time of soft start/stop operation
NOTE: Only active if Block 1, DIP 3 is set to ON
Block 2, DIP Switch 1 – Single or Dual Gate
ON – Dual gate applications
OFF* – Single gate applications
Block 2, DIP Switch 2 – Pull-to-Open or Push-to-Open
for Primary Gate Operator
ON – Primary gate operator set up for push-to-open
operation
OFF* – Primary gate operator set up for pull-to-open
operation
Block 2, DIP Switch 3 – Pull-to-Open or Push-to-Open
for Secondary Gate Operator
ON – Secondary gate operator set up for push-to-open
operation
OFF* – Secondary gate operator set up for pull-to-open
operation
NOTE: Only active if Block 2, DIP Switch 1 is set in the
ON position
Block 2, DIP Switch 4 – Timing of Dual Gates
ON – One gate is delayed when opening or closing
OFF* – Gates open and close simultaneously
NOTE: Only active if Block 2, DIP Switch 1 is set in the
ON position
Figure 16
DIP Switches
Block 1
NOTE: All DIP Switches are
shown in the factory default
position (OFF)
Block 2, DIP Switch 5 – Sequencing of Dual Gate
Opening and Closing
ON – Secondary gate operator opens first and closes
second (2 second delay)
OFF* – Primary gate operator opens first and closes
second (2 second delay)
NOTE: Only active if Block 2, DIP 4 is in the ON position
Block 2, DIP Switch 6 – Dual Gate Position Limit
Settings
ON – Set limit setting for secondary gate operator
OFF* – Set limit setting for primary gate operator
NOTE: Only active if Block 2, DIP Switch 1 is set in the
ON position
Block 2, DIP Switch 7 – Constant or Momentary
Pressure
ON – Constant pressure required to operate gate
OFF* – Momentary contact required to operate gate
Block 2, DIP Switch 8 – Not Used