Menu explanations

The MAIN MENU display
Display:
CO2 ECO
SANYO
ROOM
(20,5c) 20,3°c
TANK TEMP
47°c
OUT TEMP
13°c
STATUS
MONDAY
20:45
MANUAL DEFROST
NO
The MENU CHOICE display
Display:
LOGG []
DIAGNOS []
SETTING []
SETTING CODE []
MANUAL []
TIME SETTING []
The LOGG MENU display
Display:
TOT OPER TIME
15351h
TOT OP COMPR
7350h
COMPR/ 24h
17h
COMPR STARTS/ 24h
20
LAST ALARMS:
1 OUT SENSOR
2
3
This is the normal display of the control system, and shows the most
important values in the system.
ROOM
35°c (20): shows the room temperature if the room sensor is
installed and chosen. Room temperature is can be changed in the
Press
or
button to make a change.
TANK TEMP: shows the temperature of the upper part of the boiler
(highest temperature).
OUT TEMP: shows the out door temperature where the sensor is
mounted. Note: at quick temperature changes the sensor has some
delay.
STATUS: shows status messages of the system if necessary.
- Without HP: heat pump is not chosen. The boiler runs for itself.
- Current reduced: displays when the main fuses in the house have over
current the electrical heat power in the boiler is reduced.
- Power reduced: after a power interruption maximum 6 kW power is
allowed in the boiler for two hours.
- Summer limit: displays if the boiler gives Domestic hot water only. The
radiator circulation pump shuts off if the summer limit temperature
(outside temp.) is exceeded.
Factory setting reset: shows 2 minutes if the factory setting is reset.
MANUAL DEFROST: Possibility to manually start a defrost operation of the
heat pump. Can be used at extreme weather conditions. The operation is
automatically interrupted after 20 minutes, or manually if the value will be set to
It is only a model of ability 9kW_HP Unit that there is this function.
LOGG: in this menu
DIAGNOS: in this menu actual values are displayed. No changes can be
made.
SETTING: in this menu all system settings are made, both for the installer
and the user.
SETTING CODE: This is a menu for the manufacturer and service people.
A code needs to get access of changing the menu values.
MANUAL: a menu for service people. In the menu all components in the
boiler can manually be operated and checked.
TIME SETTING: if temperature decrease during nights is chosen, time
has to be set within this menu.
General: the LOGG menu is a long time log of the system. The values
are stored in a memory and not affected of power interrupt.
TOT OPER TIME: counts the total operating time in hours that the the
Tank unit has been under power.
TOT OP COMPR: counts the total time in hours the compressor has
been running.
COMPR/ 24h: stores the time during the last 24 hours that the
compressor has been running. The value is stored once per day.
COMPR STARTS/ 24h: counts the numbers of starts the compressor
has had during the last 24 hours. The value is stored once a day.
LAST ALARMS: shows the last alarms in order. No 1 is the latest
Alarm
Explanation
Explanation
ged.
Explanation
u