In the standard CM Zone Pack the HR80's Radiator Controllers are pre-bound to each zone as indicated by the zone number label.
To add additional HR80UK Radiator Controllers to a zone refer to Section 8: Changing the Configuration.
a
1
Turn the locking knob
and separate
a
the operating module from the coupling
module.
The HR80UK Radiator Controller provides local room temperature control based upon
setpoint information received from the CM67z Room Unit and sends Load Demand
signals based upon room conditions to the HC60NG Relay Module. Setpoints can be
temporarily overridden using the adjustment dial.
The HR80UK can be fitted onto Honeywell VT15, VT117, VT200 and many other manu-
facturers TRV bodies with a M30x1.5mm thread and a 12.9 - 10.5 mm valve closing point,
adaptors may be available for manufacturers with non standard connections, for more infor-
mation contact Honeywell Technical Help Desk, details on the back page.
When selecting the operating site ensure that the distance to wireless
!
devices such as wireless headphones, cordless phones etc. is approx.
1-2m according to the DECT standard.
Caution!
b
c
a
Turn the coupling module wheel
clockwise (approx. 3 rotations) until the
nose
reaches the end stop
b
a
1
Fit the operating module onto the cou-
pling module and turn the locking knob
down to lock in place.
a
5
Section 6: HR80UK Radiator Controller
anti-
a
.
c
The HR80UK automatically adapts to
the TRV stroke.