AEG 2020 D Operating And Installation Instructions
AEG 2020 D Operating And Installation Instructions

AEG 2020 D Operating And Installation Instructions

Cooker hood

Advertisement

Quick Links

2020 D
Cooker Hood
Operating and Installation
Instructions

Advertisement

Table of Contents
loading

Summary of Contents for AEG 2020 D

  • Page 1 2020 D Cooker Hood Operating and Installation Instructions...
  • Page 2 For the User For the Installer Important Safety Information Installation Instructions Technical Information Your Appliance Electrical Connections Operating Instructions Electrical Requirements Electrical Connection Cooker Hood Controls To Operate Installing the Cooker Hood Recirculation Extraction Installation Requirements Unpacking Maintenance and Cleaning Clearance Height Selecting the Type of Installation External Cleaning...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION These warnings are provided in the interests of your safety. Ensure that you understand them all before installing or using this appliance. Your safety is of paramount importance. If you are unsure about any of the meanings of these warnings contact the Customer Care Department. Installation Child Safety •...
  • Page 4: Your Appliance

    YOUR APPLIANCE OPERATING INSTRUCTIONS This cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. To obtain the best performance it is advisable to switch on the hood a few minutes before you start cooking and leave it running for approximately 15 minutes after finishing.
  • Page 5: Operating Instructions

    OPERATING INSTRUCTIONS This cooker hood can be used to recirculate or extract contaminated air. Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted. The contaminated air is cleaned by passing through the filters and than back into the kitchen.
  • Page 6: Maintenance And Cleaning

    MAINTENANCE AND CLEANING Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. The cooker hood must be kept clean, a build up of grease or fat can be a fire hazard. External Cleaning The metal casing, grille and chimney should be cleaned at least once a month to keep it looking like new.
  • Page 7 MAINTENANCE AND CLEANING To Remove the Charcoal Filter Push inwardly on the two retaining clips to disengage the security fixing and remove. This appliance can be a fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended. S07_31 Worktop Lighting The lamps should be replaced with a 220-240V 20W...
  • Page 8: Something Not Working

    If you require an engineer or wish to purchase spare For general assistance with your appliance or for parts contact your local Service Force Centre by information on other AEG products please contact our telephoning: Customer Care Department. Customer Care Department...
  • Page 9: Standard Guarantee Conditions

    Standard Guarantee Conditions We, AEG, undertake that if within 12 months of the date of the purchase this AEG built-in appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, the company will, at our option, repair or replace the same FREE OF ANY CHARGE for labour, materials and carriage on condition that: •...
  • Page 10: Installation Instructions

    INSTALLATION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this product in any way. Technical Information DIMENSIONS HEIGHT (CANOPY): 73 mm HEIGHT (CHIMNEY): 450-850 mm WIDTH (CANOPY): 898 mm WIDTH (CHIMNEY): Ø200-Ø270 mm GROSS: 24.00 kg NET: 19,40 kg ELECTRICAL SUPPLY:...
  • Page 11: Installing The Cooker Hood

    INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood.
  • Page 12: Clearance Heights

    INSTALLING THE COOKER HOOD Clearance Heights The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated, provided the maximum output of the appliance beneath does not exceed the maximums quoted in the Technical Specifications.
  • Page 13: Installing Instructions

    INSTALLING INSTRUCTIONS Fixing the Chimney to the Canopy Remove the metal grease filter cassette by pushing inwardly on the two steel handles. To remove the charcoal filter push inwardly on the two retaining clips to disengage the security fixing and remove. Align the fixing points on the chimney with the corresponding fixing points on the canopy.
  • Page 14: Top Shelf

    INSTALLING INSTRUCTIONS Slide the chimney through the hole in the shelf before fixing it to the canopy. Top Shelf The top shelf only requires drilling if the hood is to be installed with the air outlet turned upwards. Use the cardboard template provided to mark the hole position on the shelf.
  • Page 15 INSTALLING INSTRUCTIONS Fix the round eyelet screws provided tightly into the holes (1). Fix bracket (S) to the fan assembly. The hood is supplied in the recirculation mode, with the recirculation grille (G) fitted over the outlet in the top of the fan assembly ready for use. Insert the 4.2x44.4mm screws to be used for fixing the fan assembly into the rawl plugs and tighten about two thirds.
  • Page 16 INSTALLING INSTRUCTIONS Mark the position on the wall and drill the hole for the ducting. To calculate the centre of the hole on the wall for the ducting, draw a horizontal line (D) through the vertical line 80mm above line (X) The round ducting to be used must be Ø125mm.
  • Page 17 INSTALLING INSTRUCTIONS Using a 8mm masonry bit, drill the holes for the canopy and fan assembly and insert the rawl plugs ready for the fixing screws. The hood is supplied with the air outlet facing the rear. To rotate the extractor to face left or right proceed as follows: Loosen the screws (V1), turn the extractor 60°...
  • Page 18 INSTALLING INSTRUCTIONS Final fixing and adjustment of the hood: Two adjustable connectors are provided at the rear of the hood. Turn the screws (V1), until the screws (V2) align with the screw holes (F2). Adjust the vertical and horizontal alignment using screws (V2).
  • Page 19: Electrical Connection And Working Test

    INSTALLING INSTRUCTIONS Electrical connection and working test: Remove the metal cover by unscrewing the four self tapping screws. Connect the ‘Push-Fit’ connectors coming from S07_24 the fan assembly to the canopy. Position the terminals as illustrated under the cover and replace the cover with the four self tapping screws.
  • Page 20 4329477 01 - 001013...