Camera Requirements; Cable Requirements; Video Transmission (Coaxial) - Bosch UHI Series Installation Manual

Hide thumbs Also See for UHI Series:
Table of Contents

Advertisement

UHI/UHO Series
5.2

Camera requirements

The cameras to be built into the housing must meet the
requirements specified in Table 5.1.
Ambient temperature
Power consumption
Voltage for low voltage
units
Voltage for high voltage
units
Weight without lens
Weight with lens
Temperature under
operating conditions
Table 5.1 Specifications for cameras
5.3

Cable requirements

5.3.1

Video transmission (coaxial)

Cable type
runs < 300m (1000 ft)
runs < 600m (2000 ft)
Cable diameter (outer)
Cable shape
Cable shield
Center conductor
DC resistance
RG-59/U
RG-11/U
Cable impedance
Certificating authority
Environmental
Temperature rating
Reference type
Table 5.2 Video cable specifications
Bosch Security Systems, Inc.
0 °C to +50 °C (+32 °F to +122 °F)
10 W (max)
12 VAC to 28 VAC; +12 VDC to
+30 VDC
100 VAC to 240 VAC
450 g max
1 kg max
-20 °C to +50 °C (-4 °F to +122 °F)
RG-59/U
RG-11/U
4.6 mm to 7.9 mm
(0.18 in to 0.31 in)
Round
>93% braided copper
Stranded or solid copper
<15 ohm/1000 m
<6 ohm/1000 m
75 ohm
UL
Outdoor rated
+80 °C (+176 °F) or greater
Belden 9259
Installation Manual
Installation | en
F.01U.167.418 | 3.0 | 2010.04
57