Operational settings

LCD Adjustment
Use the arrows up and down to adjust the display's
contrast and brightness.
Software version
This shows the version of the software in the terminal
and the two control modules.
Tuning
The following components can be adjusted in the
Service Menu under Tuning.
• C1-C5 (Cylinder 1-5)
• Rot. (Rotation tower)
• Outriggers
• Tool
• Track L/R
• Joystick L/R
• System
C1-C5, Rot., Outriggers, Tool, Track L/R
Ramp
Ramp adjusts the acceleration of the drive. The higher
the ramp value the slower the acceleration.
Max./min. current
Max./min. current indicates the current interval that
governs the prop. valve.
A high minimum value means that the valve opens
rapidly. This might mean that it is not possible to em-
ploy a function gently.
A low maximum value means that the valve does not
open entirely and that the function cannot be run at
maximum speed.
A high maximum value means that the valve's maxi-
mum opening position is achieved more rapidly.
P/I value
The P and I values are the parameters that govern the
regulator. P is proportional regulation and I is integrat-
ing regulation.
High values of P and I produce a faster response but
can lead to oscillating movements.
34
- English
SETTINGS
Joystick L/R
Pos. and Neg. Progression
Pos. and Neg. Progression indicate the sensitivity of
the joystick. The higher the value the more sensitive
the joysticks are in their outer positions.
Deadband
Deadband indicates the position in which the joysticks
start to be activated. The higher the value the farther
out from neutral position that the joysticks are acti-
vated.
System
Oiltemp high
Oiltemp high
ceives the service message "Oil temperature is above
T
" in the display.
high1
Oiltemp high
Oiltemp high
ceives the service message "Oil temperature is above
T
" in the display.
high2
Oiltemp
low
Oiltemp
low
the service message "Oil temperature is below T
the display.
Restore default
Restore default restores all values in the Tuning menu.
1
is the limit level where the operator re-
1
2
is the limit level where the operator re-
2
is the limit level where the operator receives
" in
low