Brother DCP-8070D Service Manual page 599

Laser fax/mfc
Hide thumbs Also See for DCP-8070D:
Table of Contents

Advertisement

<WSW16> (Function setting 1)
Selector No.
1
Not used.
ITU-T (CCITT) superfine
2
recommendation
3
I
Not used.
6
7
Max. document length limitation
[Stop/Exit] button pressed
8
during reception
• Selector 2: ITU-T (CCITT) superfine recommendation
If this selector is set to "1," the machine communicates in ITU-T (CCITT) recommended
superfine mode (15.4 lines/mm). If it is set to "0," it communicates in native superfine
mode.
• Selector 7: Max. document length limitation
This selector is used to select the maximum length of a document to be sent.
• Selector 8: [Stop/Exit] button pressed during reception
If this selector is set to "1," pressing the [Stop/Exit] button can stop the current receiving
operation. The received data will be lost.
<WSW17> (Function setting 2)
Selector No.
1
Off-hook alarm
(Not used.)
2
3
Not used.
4
5
Calendar clock type
6
Not used.
7
Non-ring reception
8
Not used.
• Selector 5: Calendar clock type
If this selector is set to "0" (USA), the MM/DD/YY hh:mm format applies; if it is set to "1"
(Europe), the DD/MM/YY hh:mm format applies: DD is the day, MM is the month, YY is the
last two digits of the year, hh is the hour, and mm is the minute.
• Selector 7: Non-ring reception
Setting this selector to "1" makes the machine receive calls without ringer sound if the
number of calling is set to 0.
Function
Function
App. 1-22
Setting and Specifications
0: OFF
1: ON
0: 400 cm
1: 90 cm
0: Not functional 1: Functional
Setting and Specifications
0: U.S.A. type 1: European type
0: OFF
1: ON
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents