8.10.2 Reversal of direction of rotation during washing
The windings are designed to provide rotation in both directions, depending on the way in which the
capacitor is connected. Each functions alternately as a primary winding and start-up winding. When reverse
rotation is required, the switching contact of the timer reverses the connection of the capacitor between the
two windings, thus reversing the direction of rotation.
Motor stopped
8.10.3 Electrical symbols
8.10.4 Circuit diagrams
Motor with traditional connection
A - B Low-speed windings
D - High-speed running windings
P - Overload cut-out
SOI/DT 2002-05 eb
Clockwise rotation
Motor
76
Counter-clockwise rotation
Motor with suppressor connection
C - Common low-speed winding
E - High-speed running winding
Capacitor
599 35 23-17