Page 1
Il est recommandé de lire attentivement ce manuel avant d'utiliser l'appareil. Conservez ce manuel. For U.S customers : For assistance, please call : 1-800-211-PANA(7262) or Register your product at : http://www.panasonic.com/register For customers in Canada : For assistance, please call : 905-624-5505...
Safety Precautions Safety Precautions .....3 FOR YOUR RECORDS Staple your receipt to this page in case you need it later. Write down the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased About the Controls on...
Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
Page 4
When the air filter is to be Do not clean the air Ventilate well when used conditioner with water. removed, do not touch the together with a stove, etc. metal parts of the unit. • It may cause an injury. •...
About the Controls on the Air Conditioner The controls will look like one of the following. Controls Model : CW-C83GU - Turns air conditioner off. Med Fan - Med speed fan operation without cooling. Low Fan - Low speed fan operation without cooling. High Cool - Cooling with high speed fan operation.
Page 6
Controls Model: CW-XC83HK CW-XC63HK Model: CW-XC83HU Model: CW-XC83GU CW-XC63HU OPERATION • To turn the air conditioner ON, push the button. Model: CW-XC78HU To turn the air conditioner OFF, push the button again. • This button takes priority over any other buttons.
The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Controller and the air conditioner. Model: CW-XC83HU Model: CW-XC63HU, CW-XC63HK Model: CW-XC78HU CW-XC83GU, CW-XC83HK...
Additional controls and important information. Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. Part B Part A CLOSE...
Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. TO REMOVE: 1.
AIR FILTER AIR INTAKE (INLET GRILLE) Model: CW-XC83HU BRACE VERTICAL LOUVER COMPRESSOR CONDENSER EVAPORATOR BASE PAN CONTROL BOARD POWER CORD Model: CW-XC63HU, CW-XC63HK CW-XC83GU, CW-XC83HK BRACE Modèle: CW-XC78HU COMPRESSOR CONDENSER EVAPORATOR BASE PAN CONTROL BOARD POWER CORD Model: CW-C83GU BRACE...
INSTALLATION How to Install the Unit 1. To prevent vibration and noise, make sure the unit is installed securely and firmly 2. Install the unit where the sunlight does not Fence shine directly on the unit. Awning 3. The outside of the cabinet must extend Cooled air Heat outward for at least 28cm (11") and there...
Cabinet Installation 1. Open the window. Mark a line on center of the window sill (or desired air conditioner location). Carefully place the cabinet on the Upper Guide window sill and align the center mark Window sill on the bottom front with the center Front Angle Fig.
Page 14
9. Attach each Frame curtain to the window sash using screws (Type C). (See Fig. 6) Type C CAUTION: DO NOT DRILL A HOLE IN THE BOTTOM PAN. The unit is designed to operate Fig. 6 with approximately 12.7mm ( ") of water in bottom pan.
Electrical Data Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut Use 15 AMP, time or remove the grounding prong delay fuse or circuit from the plug. breaker. Power supply cord with Standard 125V, 3-wire grounding 3-prong grounding plug receptacle rated 15A, 125V AC USE OF EXTENSION CORDS...
Electrical Safety (Applies to USA only) IMPORTANT Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if (PLEASE READ CAREFULLY) you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED...
Before you call for service... Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high.
Page 18
5770 Ambler Drive, Mississauga, Ontario L4W 2T3 PANASONIC PRODUCT - LIMITED WARRANTY Panasonic Canada Inc. warrants this product to be free from defect in material and workmanship and agrees to remedy any such defect for a period as stated below from the date of original purchase.
ALL OTHER COMPONENTS: ONE (1) YEAR - PARTS AND LABOR In-home service in the USA can be obtained during the warranty period by contacting a Panasonic Service Company (PASC) Factory Servicenter listed in the Servicenter Directory. Or call toll free, 1-800-211-PANA(7262), to locate a PASC authorized Servicenter.