Control Input/Output Signals And Circuit - Mitsubishi HS-1168E Installation And Operation Manual

Time lapse video cassette recorder
Hide thumbs Also See for HS-1168E:
Table of Contents

Advertisement

Control Input/Output Signals and Circuit

ALM/RST/REC IN terminals (screw)
Active
: When input terminals are short-circuited to
GND or "L" level voltage (0 to + 1.6 V) applied.
Time for active : 0.1 sec. or over.
Non active
: Open the input.
ALM/MODE/CALL OUT terminals (screw)
Active
: "L" level voltage (0 to + 0.4 V) output; max.
drive current 50 mA (+5 V DC)/10 mA (+24 V
DC)
Non active
: Open; max. voltage +24 V DC
CLK OUT terminals (screw)
CLK OUT signal
• When F is selected in CLOCK OUT of REAR TERMINAL
menu (at 3H or 4H mode).
• During recording in L12H-224H or 0H mode.
• When REC-1 to REC-60 is selected in CLOCK OUT of REAR
TERMINAL menu (at 3H or 4H mode).
Reference page
ALM/RST/REC IN
GND
<Interface circuit inside the VCR>
<Interface circuit inside the VCR>
<Interface circuit inside the VCR>
+12 V
0 V
+12 V
0 V
+12 V
0 V
DC 5 V
10 kΩ
22 kΩ
0.047 µF
22 kΩ
ALM/MODE/CALL OUT
GND
DC 12 V
10 kΩ
CLK OUT
10 kΩ
GND
10 ms
8 ms
20 ms
31