Panasonic PT-RZ470EK Operating Instructions Manual page 112

Functional manual
Hide thumbs Also See for PT-RZ470EK:
Table of Contents

Advertisement

Example of the E-mail sent for an error
The following E-mail is sent when an error has occurred.
=== Panasonic projector report(ERROR) ===
Projector Type
Serial No
----- check system -----
MAIN CPU BUS
FAN
INTAKE AIR TEMPERATURE
OPTICS MODULE TEMPERATURE
INTERNAL AIR TEMPERATURE
LIGHT STATUS
INTAKE AIR TEMP.SENSOR
OPTICS MODULE TEMP.SENSOR
INTERNAL AIR TEMP.SENSOR
BATTERY
PHOSPHOR WHEEL
(Error code 00 00 00 00 00 00 00 00 00 00 00 02 00 00 00 00)
Intake air temperature
Optics module temperature
Internal air temperature
PROJECTOR RUNTIME
-------- Current status --------
MAIN VERSION
NETWORK VERSION
SUB VERSION
POWER STATUS
INPUT SIGNAL
SIGNAL NAME
SIGNAL FREQUENCY
----- Wired Network configuration -----
DHCP Client
IP address
MAC address
Mon Jul 05 14:11:29 2012
----- Memo -----
[ECO management set up] page
You can perform settings for the ECO management function of the projector.
Click [Detailed set up] → [ECO management set up].
1
[LIGHT POWER]
Select the light source power setting.
2
[AUTO POWER SAVE]
Select [ON] to set [AMBIENT LIGHT DETECTION], [SIGNAL
DETECTION], and [AV MUTE DETECTION].
3
[AMBIENT LIGHT DETECTION]
Enables ([ON])/disables ([OFF]) the ambient light detection
function.
Note
f For detailed description of each setting item, refer to the [PROJECTOR SETUP] menu of the projector → [ECO MANAGEMENT]
(x page 77).
112 - ENGLISH
Chapter 4 Settings — [NETWORK] menu
: RW430
: SW1234567
[ OK
]
[ OK
]
[ OK
]
[ OK
]
[ OK
]
[ OK
]
[ OK
]
[ FAILED ]
[ OK
]
[ OK
]
[ OK
]
:[
18 degC /
64 degF ]
:[
30 degC /
86 degF ]
:[
28 degC /
82 degF ]
9 H
1.00
1.00
1.00
POWER=STANDBY
DVI-I
XGA60
48.36kHz / 60.00H
OFF
192.168.0.8
04:20:9A:00:00:00
1
2
3
4
5
6
7
4
[SIGNAL DETECTION]
Enables ([ON])/disables ([OFF]) the signal detection function.
5
[AV MUTE DETECTION]
Enables ([ON])/disables ([OFF]) the AV mute detection function.
6
[NO SIGNAL SHUT-OFF]
Select the time until the projector enters the standby mode
when the signal detection function is used.
7
[Submit]
Update the settings.

Advertisement