Switch Examples
SW1
485 3
NE 3
485 4
NE 4
Figure 2: RS422/485 Interface Configuration
485
Mode Selection
OFF :
422 Mode
The transmitter lines TX+ and TX- are always driven
ON :
485 Mode
The transmitter lines TX+ and TX- are switched to high
impedance when the device is not actively transmitting data
NE
485 option, OFF for 422
OFF :
The receiver is always enabled.
receiver will echo back all transmitted data.
ON :
The receiver is disabled when the transmitter is enabled. In a
two-wire setup the receiver will not echo back transmitted data.
Note: Switch positions 1 and 2 are for port 1 and switch positions 3 and 4 for port
2 on SW3. Switch positions 1 and 2 are for port 3 and switch positions 3 and 4 for
port 4 on SW1.
OMG-USB-SER-4
Configuration
SW3
485 1
NE 1
485 2
NE 2
In a two-wire setup the
Page 6