APPLICATION
The W8600F Air Cleaner Monitor is an option available
for use with the F50F and F52F Honeywell Electronic Air
Cleaners (EAC). The series two F50F and F52F require
a solid state power supply that is compatible with the
W8600F driver board. Any series one F50E, F or F52F
can be upgraded to use the W8600F when the power
supply is replaced and the driver board (included in
W8600F kit) is installed.
The W8600F function indicator panel has four liquid
crystal display (LCD) arrowheads that point to ON,
BATTERY, SERVICE or FAULT. See Fig. 1. The
arrowheads darken to indicate the existing EAC
condition. See Table 1.
INSTALLATION
When Installing this Product..
1. Read these instructions carefully. Failure to follow
the instructions could damage the product or cause
a hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application
3. Installer must be a trained, experienced service
technician.
4. After completing the installation, use these instruc-
tions to check out the product operation.
Location
The styling of the W8600F is designed to blend with the
latest T8600 family of Honeywell Chronotherm¨ IV
Deluxe Programmable Thermostats. A special mounting
template is included for mounting next to the T8600. The
W8600F can also be mounted at any other convenient
location in the living area or equipment room. See Fig. 2.
NOTE: The W8600F shares no common electrical con-
nections with the thermostat.
® U.S. Registered Trademark
Copyright © 2002 Honeywell International Inc. •
W8600F Air Cleaner Monitor
• All Rights Reserved
INSTALLATION INSTRUCTIONS
ON
BATTERY
SERVICE
FAULT
Air Cleaner Monitor
Fig. 1. W8600F Air Cleaner Monitor features.
Table 1. Description of W8600F Function Indicator
Indicators
ON
EAC is powered and system blower is
running.
BATTERY
Battery that maintains W8600F
memory is low and needs to be
replaced.
SERVICE
EAC prefilter and cells need to be
washed
FAULT
•Shorting of collector plates.
•Continuous ionizer or collector plate
arcing.
•Power supply failure.
•Excessive current.
•Major reduction in high voltage.
•EAC prefilter and cells are past
SERVICE level of dirt and need to be
washed immediately.
Call a service technician.
a
The reset button is located on the bottom of W8600F.
After the prefilters and cells are cleaned and reinstalled,
press this button to turn off the SERVICE indicator and
reset the wash frequency timer.
LCD
FUNCTION
INDICATOR
PANEL
RESET BUTTON
M11965
Panel.
Condition
a
.
69-1200-2

Advertisement

loading

Summary of Contents for Honeywell W8600F

  • Page 1 Location SERVICE EAC prefilter and cells need to be The styling of the W8600F is designed to blend with the washed latest T8600 family of Honeywell Chronotherm¨ IV Deluxe Programmable Thermostats. A special mounting FAULT •Shorting of collector plates.
  • Page 2 1. Hold the mounting template (included in the W8600F kit) next to the T8600 as shown in Fig. 3. 2. Mark the holes for the screw anchors and the WIRING HOLE 3-conductor thermostat cable.
  • Page 3 Refer to Table 2 to select the wash frequency. Set the damage. W8600F DIP switches to match the selection. See Fig. 4. Disconnect EAC power and open the access The time listed represents actual run time of the EAC, not door before opening power supply box cover.
  • Page 4: System Checkout

    W8600F AIR CLEANER MONITOR 12. Connect the three wires from the W8600F to the 3. Connect terminal 3 to terminal 4 and the function EAC terminals 1, 3 and 4. panel indicates ON. FAULT will turn off. 4. Disconnect terminal 3 from terminal 4. The NOTE: Connect terminal 1 to 1, 3 to 3 and 4 to 4.