Summary of Contents for Honeywell TC150

  • Page 1: Table Of Contents

    Honeywell Wireless Rain Gauge (TC150) USER MANUAL TABLE OF CONTENTS INTRODUCTION PRODUCT OVERVIEW REMOTE RAIN GAUGE REMOTE SENSOR BEFORE YOU BEGIN BATTERY INSTALLATION REMOTE TEMPERATURE SENSOR MAIN UNIT LOW BATTERY WARNING HOW TO USE THE TABLE STAND GETTING STARTED REMOTE AND INDOOR TEMPERATURES...
  • Page 2: Introduction

    INTRODUCTION Thank you for selecting the Honeywell Wireless Rain Gauge. This device monitors and displays rainfall data along with the indoor/outdoor temperature from up to three remote locations. In this package you will find: • One main unit (receiver) • One remote rain gauge (transmitter) •...
  • Page 3 FRONT VIEW (RAIN MODE CONTROL PANEL) A. WEATHER AND TIME INFORMATION IN A THREE - LINE LCD DISPLAY B. ALARM button • Toggles between the rainfall modes – a current rainfall data and a rain alarm programming mode • Activates the high rainfall alarm setting mode MODE button •...
  • Page 4 REAR VIEW (TIME AND TEMPERATURE CONTROLS PANEL) H. MODE button Toggles between four clock modes – time with seconds, time with the day of the week, Time Zone programming and calendar I. UP (▲) button • Increases all time and temperature function parameters •...
  • Page 5: Remote Rain Gauge

    REMOTE RAIN GAUGE FEATURES • Precipitation measurement • Remote rainfall data transmission to the main unit via 433 MHz signal • 100 feet (30 meters) transmission range without interference • Built-in installation level • Mounting hardware • Non-corrosive protective screen A.
  • Page 6: Remote Sensor

    I. Protective screen Protects the rain gauge funnel from debris REMOTE SENSOR FEATURES • Remote temperature transmission to the main unit via 433 MHz signal • 100 feet (30 meters) transmission range without interference • LCD display of measured temperature •...
  • Page 7: Battery Installation

    the temperature sensor) and the main unit within the effective transmission range of 100 feet (30 meters). • The remote rain gauge must be placed outdoors on the open area, away from the walls, fences and trees and level. • It is important that excess precipitation can freely flow from the remote rain gauge.
  • Page 8: Remote Temperature Sensor

    REMOTE TEMPERATURE SENSOR NOTE: Install the batteries; select the channel and temperature in C° or F° before mounting the remote temperature sensor. • Remove the screws from the battery compartment with a small Phillips screwdriver. • Set the channel. The switch is located in the battery compartment.
  • Page 9: Remote And Indoor Temperatures

    REMOTE AND INDOOR TEMPERATURES The remote temperature information is located on the middle line of the main unit’s display. The indoor temperature with the icon IN is located next to the remote temperature. The wave icon above the remote channel number indicates the reception status from the remote temperature sensor.
  • Page 10: Maximum And Minimum Temperature

    MAXIMUM AND MINIMUM TEMPERATURE The maximum and minimum record of the indoor and remote temperatures will be automatically stored in the memory of the main unit. To display the minimum, maximum or the current reading press MEMORY button on the back panel. To clear the memory, press and hold MEMORY button on the back for two seconds and all previously stored readings will be erased.
  • Page 11: Manual Settings

    MANUAL SETTINGS CLOCK • Press and hold MODE button for 3 seconds: the language letters will flash. • Press UP (▲) or DOWN (▲) to change flashing letters. • After the first value is set, press MODE button again to move to the next value •...
  • Page 12: Snooze

    alarm time will be set. • Set Single day alarm if desired in the same manner. SETTING THE ICE WARNING ALARM If Weekday or Single day alarm is set, the Ice Warning Alarm can be programmed. • Press the back panel ALARM button once to enter into the Ice Warning Alarm setting mode.
  • Page 13: Specifications

    SPECIFICATIONS Main Unit TIME 12/24 hour display in hh: mm format Date format: month-day or day-month format Day of the week is selectable in five languages (English, Spanish, French, German, Italian) Time zone manual adjustment Dual two-minute crescendo alarms with 8 minutes snooze Programmable ice warning alarm (Channel 1) WEATHER Rainfall...
  • Page 14: Fcc Statement

    Name: Hideki Electronics, Inc. Address: 7945 SW Mohawk, Tualatin, OR 97062 Telephone No.: 1-503-612-8395 declare that the product Product No.: TC150 Product Name: Wireless Rain Gauge Manufacturer: Hideki Electronics Ltd. Address: Unit 2304-06, 23/F Riley House, 88 Lei Muk Road, Kwai Chung, New Territories, Hong Kong is in conformity with Part 15 of the FCC Rules.
  • Page 15: Standard Warranty Information

    Copyright (2006) Hideki Electronics Inc. All Rights Reserved. The Honeywell Trademark is used under license from Honeywell Intellectual Properties Inc. Honeywell International Inc. makes no representations or warranties with respect to this product.

Table of Contents