Setting F/C Indication And Heat Cycle Rate; Optional System Checkout; Set Temperature Setpoint - Honeywell T8411R Installation Instructions Manual

Electronic heat pump thermostat
Hide thumbs Also See for T8411R:
Table of Contents

Advertisement

The temperature setpoint and the room temperature are
shown separately on the digital display. The
points to Set when the temperature setpoint is displayed
and to Room when the room temperature is displayed.
INDICATOR
ROOM TEMPERATURE
Set
Room
SETPOINT TEMPERATURE
To set temperature setpoint:
1. Select heat or cool by sliding the SYSTEM switch
in the lower right corner of the thermostat to the
desired mode. See Fig. 7.
2. To display the setpoint temperature on the
digital display, press either the
The temperature setpoint is displayed for approxi-
mately five seconds as the indicator points to Set
and flashes.
M11248
3. To increase the setpoint temperature, press the
key. Press once to change the setpoint one
degree; press and hold to change the setpoint
several degrees.
M11249
4. To decrease the setpoint temperature, press the
key.
M11250
°
°
Setting
F/
C Indication and Heat Cycle Rate
NOTES: To save changes to the °F/°C indication and the
heat cycle rate, all seven steps must be
completed.
In installer setup mode steps 2. through 5., each
press of the
key momentarily displays 01 and
each press of the
02. When the keys are released, these two-digit
codes are no longer displayed.
To set the °F/°C indication and heat cycle rate:
1. If the room temperature is displayed in °F, set the
temperature setpoint to 52°F. If the room tempera-
ture is displayed in °C, set the temperature setpoint
to 11°C.
indicator
M11247
or
key once.
key momentarily displays
M11251
T8411R ELECTRONIC HEAT PUMP THERMOSTAT
2. Press the
keys simultaneously for more than
two seconds to light all segments on the display and
to enter installer setup mode. When the keys are
released, a two-digit software code is displayed
(code displayed may vary).
M11252

Optional System Checkout

CAUTION
When the heat or cool outputs are turned on, the
five-minute off-timer safety feature is bypassed.
When in steps 2. and 3. only, the
used to turn heat or cool outputs on. Change the
system switch setting to test heat or cool outputs.
No action takes place if the system switch is in
the Off position.
The following examples of system settings show a two
digit software code on the display. The code shown is only
an example; codes may vary.
System setting at Heat:
To turn heat on, press the
M11469
To turn auxiliary heat on, press the
Aux Ht
M11470
To turn auxiliary heat off, press the
M11469
To turn heat off, press the
M11255
System setting at Cool:
To turn cool on, press the
M11256
To turn cool off, press the
M11255
3. Press the
key. Factory information is displayed.
Information displayed varies by model. This
information is only for factory use.
5
M11255
key can be
key.
key.
key a third time.
key a fourth time.
key.
key.
69-1037