Honeywell MAGICSTAT CT2400 Programming And Installation Instructions page 12

Weekday/weekend (5-day/2-day) programmable heat and/or cool low voltage (20 to 30 vat) thermostat and mounting plate
Table of Contents

Advertisement

COOLING
To avoid possible compressor
damage, do not operate the
cooling system when outside
temperature is below 50° F
[1 O" C]. See compressor manu-
facturer instructions for further
information.
NOTE: When cooling setting is
changed, thermostat may delay
up to five minutes before
turning on the air conditioner.
This delay protects the com-
pressor.
First set the fan switch.
Then set the system switch.
Move the system switch to COOL
and the fan switch to AUTO.
Temp
Press key until setting is about 10°
F [6° C] below room temperature.
The cooling equipment and fan
should start.
Temp
Press key until the setting is about
10° F [6° C] above room tempera-
Warmer
ture. The cooling equipment and
fan should stop.
Move the system switch to OFF
with the fan switch still at AUTO. . .
The system and fan should be off.
26
FAN AUTO: Normal setting for most
homes. A sinale-sDeed fan will turn on ~
furnace. A two-speed fan will usually
run on high with air conditioner and on
low with furnace.
Exception: When Fan Operation
Switch on back of thermostat is set to
"E" position (see page 16), fan will
operate with furnace only.
FAN ON: The fan runs continuously.
Use for improved air circulation during ~
special occasions or for more efficient
electronic air cleaning. (In a heat-only
system, fan will run continuously only
when fan relay is connected to the
thermostat.)
27
COOL: The thermostat controls your
air conditioning system.
OFF: Both the heating and air
conditioning systems are off.
HEAT: The thermostat controls your
heating system.
28
Auto On