F300E ELECTRONIC AIR CLEANER
10. Plug the driver board assembly into the J1 power
supply connector.
11. Replace the power supply box cover.
12. Connect the three wires from the W8600F to the EAC
terminals 1, 3 and 4. See Fig 12.
ELECTRONIC AIR CLEANER
TERMINAL STRIP
ON POWER BOX
GREEN
1
CONNECT TO W8600F TERMINALS BEFORE CONNECTING TO
POWER BOX.
Fig. 12. Wiring W8600F to F300E power box
terminal strip (two-cell model).
NOTE: Connect terminal 1 to 1, 3 to 3 and 4 to 4.
13. Turn on the EAC power.
14. Turn on the system fan.
15. Push the W8600F reset button. All four indicators on
the display will flash 5 times. The ON indicator will stay
active as long as the EAC and system fan are on. See
Fig. 13.
Fig. 13. Complete T8600/W8600F installation.
OR Install Optional W8600A-1007
AIRWATCH™ Indicator
The W8600A AIRWATCH Indicator is an option available for
use with the F300E. It is a battery-operated timer. Installation
only requires drilling holes in the wall to mount the device.
68-0240-1
W8600F
1
1
4
3
RED
BLUE
THREE-WIRE
THERMOSTAT CABLE
M11974
M15586
The W8600A function indicator panel has four liquid crystal
display (LCD) arrow indicators that point to Battery, Air
Cleaner, UV Air Treatment, and Humidifier. See Fig. 14. The
blinking arrowheads indicate the devices that need service.
See Table 5.
Table 5. W8600A.
If arrow is flashing
LCD
or unit
is beeping...
Battery
Batteries need
changing
Air Cleaner
Media filter needs
replacing or
electronic filter
needs washing.
UV Air
UV lamps need
Treatment
replacing in UV air
treatment system.
Humidifier pad
Humidifier
needs replacing.
NOTE: The W8600A beeps whenever an arrow is blinking
to alert you to identify the device that needs
service. After servicing, press the reset button at
the botton of the W8600A and hold for 10 seconds
to reset the timer.
Battery
Air Cleaner
UV Air Treatment
Humidifier
Honeywell.com/yourhome
Fig. 14. W8600A AIRWATCH Indicator features.
Set DIP Switches
1. Set then DIP switches according to equipment
installed in the home:
a. Use default position set at the factory when
alldevices (air cleaner, UV air treatment system,
humidifier) are installed in the home.
b. Move DIP switch to left (off position) when adevice
is not installed in the home.
10
Rset by...
Changing batteries
within 30 seconds of
removing old
batteries to maintain
correct indication
time.
Pressing and holding
reset button for 10
seconds or until
arrow is no longer
displayed.
LCD
TM
FUNCTION
INDICATOR
PANEL
RESET BUTTON
M14696