Pioneer KEH-P580 Service Manual page 42

Multi-cd control high power cassette player with fm/am tuner
Hide thumbs Also See for KEH-P580:
Table of Contents

Advertisement

KEH-P580,P5800,P5850
Modulation M:MONO MOD., 400Hz 30%(22.5kHz Dev.) or 400Hz 100%(75kHz Dev.)
S:STEREO MOD., 1kHz, L or R=30%(20.25kHz+7.5kHz Dev.)
NOTE:Before proceeding to further adjustments after switching power ON, let the tuner run for ten minutes to allow
the circuits to stabilize.
FM ADJUSTMENT(UC MODEL)
No.
Frequency(MHz)
1
•••••
TUN Volt
IF
2
98.1 M
3
98.1 M
ANT Coil
4
98.1 M
RF Coil
IFT
5
98.1 M
ARC
6
98.1 S
FM ADJUSTMENT(ES MODEL)
No.
Frequency(MHz)
1
•••••
TUN Volt
IF
2
98.1 M
3
98.1 M
ANT Coil
4
98.1 M
RF Coil
IFT
5
98.1 M
ARC
6
98.1 S
DOLBY B NR ADJUSTMENT
No.
Test Tape
1
NCT-150
(400Hz,200nwb/m)
42
FM SSG
Displayed
Level(dBf)
Frequency(MHz)
•••••
60
100
5
5
5
40
FM SSG
Displayed
Level(dBf)
Frequency(MHz)
•••••
60
100
5
5
5
40
Adjustment Point
VR301(Lch),VR302(Rch)
Adjustment
Point
107.9
L5
98.1
T51
98.1
L2
98.1
L4
98.1
T31
98.1
VR154
Adjustment
Point
108.0
L5
98.1
T51
98.1
L2
98.1
L4
98.1
T31
98.1
VR154
mV Meter(2) : –6dBs±1.0dB
Adjustment Method
(Switch Position)
DC V Meter(1) : 6V
Center Meter : 0
mV Meter(1) : Maximum
mV Meter(1) : Maximum
mV Meter(1) : Maximum
(STEREO MODE)
mV Meter(1) : Separation 5dB
(STEREO MODE)
Adjustment Method
(Switch Position)
DC V Meter(1) : 6V
Center Meter : 0
mV Meter(1) : Maximum
mV Meter(1) : Maximum
mV Meter(1) : Maximum
(STEREO MODE)
mV Meter(1) : Separation 5dB
(STEREO MODE)
Adjustment Method
(Switch Position)
(DOLBY NR Switch : OFF)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Keh-p5850Keh-p5800