Troubleshooting A Wet Enclosure - Dell PowerEdge C8220X Hardware Owner's Manual

Servers
Hide thumbs Also See for PowerEdge C8220X:
Table of Contents

Advertisement

Troubleshooting a Wet Enclosure

CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
1 Turn off the sleds and attached peripherals.
2 Disconnect the enclosure from the electrical outlet or the PDU.
CAUTION:
Wait until all of the indicators on the power supplies turn off before
proceeding.
3 Remove all sleds. See "Removing a Sled" on page 155.
4 Open the sled. See "Removing the Front and Back Sled Covers" on
page 176 or "Removing the Sled Cover" on page 181.
5 Disassemble components from the sled. See "Installing System
Components" on page 149.
Hard-drives
Cooling shroud
Processors and heat sinks
Memory modules
Expansion card/RAID controller card
GPGPU/Xeon Phi card
Mezzanine card
Interposer extender
Internal hard-drives
Power distribution board
MicroSD card reader
6 Remove all server enclosure components. See the PowerEdge C8000
Systems Hardware Owner's Manual for more information.
7 Let the sled dry thoroughly for at least 24 hours.
Troubleshooting
337

Advertisement

Table of Contents
loading

Table of Contents