(3) Remove the two cup S M3x6 Taptite screws, and then remove the Transfer HVPS PCB
unit.
8.11 Registration-mark Sensor PCB ASSY 1, 2/ Density Sensor/ Registration
Relay PCB ASSY/ Transfer HVPS PCB ASSY
(1) Remove the bind B M3x8 Taptite screw, and then remove the Earth plate 3.
Transfer HVPS PCB unit
Fig. 3-32
Earth plate 3
Fig. 3-33
Transfer HVPS PCB unit
Taptite, cup S M3x6
Taptite, bind B M3x8
3-51
<Back side>
Taptite, cup S M3x6
Confidential