Fujitsu D3081 Technical Manual

For primergy rx900 s1

Advertisement

Quick Links

Technical Manual - English
Baseboard D3081, CPUMEMR D3131,
PCIR D3082 for PRIMERGY RX900 S1
Technical Manual
Edition August 2010

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D3081

  • Page 1 Technical Manual - English Baseboard D3081, CPUMEMR D3131, PCIR D3082 for PRIMERGY RX900 S1 Technical Manual Edition August 2010...
  • Page 2 All hardware and software names used are trademarks of their respective manufacturers. – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.
  • Page 3 It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 4 (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
  • Page 5 Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 6 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 7: Table Of Contents

    Screen resolutions ..... . . 48 Temperature / System monitoring ....48 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 8 External connectors and indicators ....57 3.7.3.1 Baseboard D3081 ..... . . 57 3.7.3.2 I/O board .
  • Page 9: Introduction

    DVDs, see Installation DVD of ServerView Suite - ServerView Software Products. You will find detailed information about the BIOS setup in the "D3081 BIOS Setup Utility for RX900 S1" manual. PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2.
  • Page 10 Introduction Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 11: Important Information

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 12 (this information doesn’t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 13 Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 14: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 15: Environmental Protection

    Important information Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    Features Overview This section provides an overview of the key characteristics for the baseboard D3081, the CPU Memory Risers (CPUMEMRs) D3131, and the PCI Riser (PCIR) D3082. Processors Up to 8 Intel Xeon® X7500/E7500 series processors (up to 130 W); one processor per CPUMEMR 4 Intel QuickPath Interconnects;...
  • Page 18 – 5x 1 GB 1000Base-T System LAN connectors – 1x 1 GB 1000Base-T Shared LAN connector – 1x 100 MB 100Base-TX Management LAN connector – I/O board: – 1x serial connector – 4x USB 2.0 connectors – 1x video connector Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 19 – PWM Control and Fan Tach Monitor – Voltage Level Monitor and Temperature Monitor – Real-Time Clock (RTC) – Two Watchdog Timers – System and Clock Control – Three Multi-Purpose Timers – Interrupt Controller – JTAG interface Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 20 Adapter fault tolerance, Load Balancing and Switch fault tolerance in combination with existing GB PCIe card is supported, based on the functionality (SW Kit) of onboard GB LAN controllers. Single root I/O virtualization (SR-IOV) for virtualization on Intel NIC. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 21 The baseboard can be equipped with a Trusted Platform Module (TPM). This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system, see the "D3081 BIOS Setup Utility for RX900 S1" manual. Technical Manual...
  • Page 22: Main Memory

    CPUMEMRs. Number of Population CPUMEMR position Air duct position CPUMEMRs order #1 + #2 + #3 + #4 #5 + #6 #7 + #8 Table 1: Population order for CPUMEMRs Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 23: Cpu Memory Riser (Cpumemr) Configuration

    DDR channel number, and the DIMM memory module number within the same DDR channel. DIMM slot Millbrook DIMM memory module number identifier channel number within the number same DDR channel Table 2: DIMM memory module connection on the CPUMEMR Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 24: Dimm Slot Population Order

    1B + 1D + 1F + 1H 1A + 1C+ 1E + 1G 2B + 2D + 2F + 2H 2A + 2C + 2E + 2G Table 3: DIMM memory module population order for an individual CPUMEMR Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 25: Dimm Slot Population Rules For Mixed Dimm Rank

    The slot with the lower sequence number is populated first. 1RANK- and 2RANK-DIMM memory modules can be inserted in both slots. 4RANK-DIMM memory modules must be installed in the slot with the lower sequence number or in both slots. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 26 1 Rank 2 Rank not installed 2 Rank 2 Rank 1 Rank 1 Rank 1 Rank not installed 1 Rank not installed not installed Table 4: Supported DIMM configurations with mixed DIMM RANK Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 27: Qpi Topology

    CPUs not included in this configuration are set to "disabled". As soon as the removed CPU has been reinstalled, the system enables all those disabled CPUs that are needed to form the next supported configuration. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 28 QPI scenarios depending on the position of the CPU that has been removed. Configurations with one to three CPUs are not to be understood as minimum configurations. They may occur due to the removal of CPUMEMRs. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 29 CPU#5 empty CPU#7 or #8 empty CPU#4 empty CPU#5 or #6 empty CPU#3 CPU#4 empty empty CPU#3 empty CPU#3 empty CPU#3 empty CPU#2 CPU#1 empty empty C1-2 C1-1 Figure 4: QPI topology transitions Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 30: Memory Configuration Modes

    DIMM# (1B, 1D, 1F, 1H) DIMM# (1A, 1C, 1E, 1G) DIMM# (2B, 2D, 2F, 2H) DIMM# (2A, 2C, 2E, 2G) B 1C B 2C Figure 5: Grouping of DIMM slots for memory mirroring Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 31 In a 6 or 8 CPUMEMR configuration, memory mirroring is configured between pairs of CPUMEMRs. Figure 7 shows the CPUMEMR mirroring pairs (1,2), (3,4), (5,6), (7,8) where each pair consists of a green and a light grey CPUMEMR. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 32 BIOS boots without mirroring configuration. 3. If the active DIMM memory modules form a valid mirroring configuration, the BIOS keeps mirroring configuration with the remaining DIMM memory modules. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 33: Hemisphere Mode

    Data is distributed over these two sections for better performance. As hemisphere mode is used for configurations with more than 4 CPUs, an even number of CPUs is necessary to configure memory-mirroring. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 34: Memory Interleaving

    CPUs and IOHs for 4, 6, and 8 CPUMEMRs. DIMM 4 CPUMEMRs 6 CPUMEMRs 8 CPUMEMRs slot pop. order CPU#1 1 CPU#2 1 CPU#3 0 Table 6: DIMM slot population order and mapping of DIMM slots to I/O Hubs and CPUs Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 35 6 CPUMEMRs 8 CPUMEMRs slot pop. order CPU#4 0 CPU#5 0 CPU#6 0 CPU#7 0 CPU#8 0 Table 6: DIMM slot population order and mapping of DIMM slots to I/O Hubs and CPUs Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 36: Pcie Slots

    CSS indicators (B) and (H). In addition, PCI hot-plug slots are equipped with the indicator (I). Figure 9: PCIe slots on the PCI Riser (A) and the baseboard (E; only PCI part is shown) Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 37: Pci Interrupt Assignment

    PCIe slots to the 4 I/O Hubs and the 4 - 8 CPUMEMRs. Before adding an expansion card, check carefully whether this PCIe slot is supported with the CPUMEMR configuration of the individual server. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 38 IOH#1 IOH#2 IOH#3 IOH#4 CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR CPUMEMR Figure 10: Assignment of PCIe slots to CPUMEMRs Figure 10 lists the mapping of PCIe slots to I/O Hubs and CPUs. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 39 PCIe slot #12 hot-plug CPU#7 #7 or PCIe slot #17 Gen2x4 CPU#8 PCIe slot #13 PCIe slot #14 PCIe slot #15 PCIe slot #16 Table 7: Mapping of PCIe slots to I/O Hubs and CPUs Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 40: Expansion Card Configuration Table

    Gen 2x8 8 Intel GbEx1 Gen 1x4 8 GbEx2 Gen 1x4 8 GbEx4 Gen 1x4 8 (*2) (*2) 10GbEx2 Gen 2x8 8 Table 8: Expansion card installation recommendation I/O Hubs IOH#1 and IOH#2 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 41 *2) The Quad LAN card consumes twice as much I/O space as a standard expansion card because it includes a bridge within the card. If you install this card into slot#1 or slot#2, no I/O resource will be assigned to the onboard GbE controller. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 42: I/O Space

    I/O space requirements where "x" indicates that I/O space is required. Please note that I/O space assignment is only needed if Legacy LAN Boot(PXE, iSCSI) and an LSI SAS/SAS_RAID card is used. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 43: I/O Space Limitation

    Auto and Disabled can be selected in the BIOS setup menu to assign I/O space for onboard devices and for PCIe slots including slot #8 for the Modular RAID controller. Auto is set for all onboard devices and PCIe slots by default. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 44 Disabled: I/O space is not assigned even if the device requests for it. If you specify auto, the I/O space is assigned in descending order of the PCI-bus number within each I/O Hub until no I/O space is left. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 45 PXE- boot from Onboard-LAN as the Intel Boot Agent ROM requires I/O space. Table 11: I/O space assignment for 4, 6, and 8 CPU configurations Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 46 PCIe slot PCIe slot PCIe slot PCIe slot IOH #3 not Max 4 Max 2 recognized PCIe slot PCIe slot PCIe slot Table 11: I/O space assignment for 4, 6, and 8 CPU configurations Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 47 IOH #4 not Max 2 recognized recognized PCIe slot PCIe slot PCIe slot PCIe slot Max 16 Max 16 Max 16 Table 11: I/O space assignment for 4, 6, and 8 CPU configurations Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 48: Screen Resolutions

    Temperature monitoring Measuring the processor temperature and ambient temperature by way of a temperature sensor. Fan monitoring The fans are monitored. Fans that are blocked, sluggish or no longer available are detected. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 49: Connectors And Indicators

    S2’s Web interface or via the ServerView Operations Manager. Connectors and indicators This section provides an overview of: "Onboard connectors and indicators" on page 50 "External connectors and indicators" on page 57 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 50: Onboard Connectors And Indicators

    Features 3.7.1 Onboard connectors and indicators 3.7.1.1 Baseboard D3081 Figure 12 shows the onboard connectors on the baseboard where the individual connectors are named in table Figure 12: Onboard connectors baseboard D3081 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 51 Front video connector (TPM) USB Flash Module (UFM) Front USB connector SATA optical disk drive CPU Memory Riser Table 13: Onboard connectors baseboard D3081 Figure 13 shows the indicators on the baseboard where the individual indicators are named in table Technical Manual...
  • Page 52 Features Figure 13: Indicators on the baseboard D3081 Pos. Indicator Pos. Indicator BMC heart beat PCI hot-plug power/fault POST code PCIe CSS Table 14: Connectors on the baseboard D3081 All the indicators are only visible after the cover has been removed.
  • Page 53: Cpu Memory Riser (Cpumemr) D3131

    CPUMEMR B 1C B 2C Figure 14: Onboard connectors and indicators CPUMEMR D3131 Pos. Connector Pos. Indicator DIMM, CPU, CPUMEMR CPUMEMR Table 15: Onboard connectors and indicators CPUMEMR D3131 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 54: Pci Riser (Pcir) D3082

    Figure 15: Onboard connectors and indicators PCIR D3082 Pos. Connector Pos. Indicator PCIe slots PCIe CSS PCIR CSS button Table 16: Onboard connectors and indicators PCIR D3082 Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 55: I/O Board

    1x USB connector 3.7.2 Onboard DIP switch Figure 17 shows the position of the DIP switch where the DIP switch settings are named in table Default setting: Switches 1 to 4 are set to Off. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 56 Switch 2 is used to define whether the password is skipped at system startup, if the password protection is enabled in the BIOS Setup (in Security menu, the Password on boot field must be set to Enabled). Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 57: External Connectors And Indicators

    18. The LAN indicators are explained in table Figure 18: External connectors of the baseboard D3081 Pos. Port Connector Pos. Indicator 1x 100 MB Management Global error indicator...
  • Page 58 (indicator description table Table 18: External connectors on the baseboard D3081 The system is equipped with one Dual 10 GB Ethernet Controller type Intel 82599. In addition, three Dual 1 GB Ethernet Controller type Intel 82576 NS (system LAN) are installed supporting transmission rates of 10 Mbit/s, 100 Mbit/s, and (only for system LAN) 1 Gbit/s.
  • Page 59 Remains dark: LAN transfer rate of 10 Mbit/s. Activity LAN link/transfer Steady green signal: (shared LAN) LAN connection exists. Remains dark: no LAN connection exists. Flashes green: LAN transfer takes place. Table 19: LAN indicators Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 60 Remains dark: LAN transfer rate of 10 Mbit/s. Activity LAN link/transfer Steady green signal: (management LAN) LAN connection exists. Remains dark: no LAN connection exists. Flashes green: LAN transfer takes place. Table 19: LAN indicators Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 61: I/O Board

    Figure 20: External connectors on the I/O board Pos. Connector 4x USB Serial COM1 Video Table 20: External connectors on the I/O board The serial connector COM1 can be used as default interface or to communicate with the iRMC S2. Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 62 Features Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 63: Replacing The Lithium Battery

    The lithium battery must then be replaced. The replacement procedure is explained in the "PRIMERGY RX900 S1 Server Maintenance Manual". Technical Manual D3081, D3131, D3082 (RX900 S1)
  • Page 64 Replacing the lithium battery Technical Manual D3081, D3131, D3082 (RX900 S1)

This manual is also suitable for:

Cpumemr d3131Pcir d3082

Table of Contents