Gas Regulator - Cobra C6 Installation And Operation Manual

Gas cooktops 600mm & 900mm
Table of Contents

Advertisement

Gas Regulator

NOTE:
The regulator supplied is convertible between
Natural Gas and LP Gas, but it's outlet pressure is
fixed ex-factory and is NOT to be adjusted.
1. Ensure that the gas supply is turned 'Off' at the
mains.
2. Unscrew the hexagonal cap (23 mm A/F) from
the regulator.
3. Un-clip the plastic pin from the cap, reverse the
pin and re-fit it back to the cap the correct way
for the gas type to be used. (Either 'LP' or 'NAT'
should be visible on the flank of the pin once re-
fitted to the cap).
4. Screw the cap back into the regulator hand
tight only.
Gas Type Identification Label
On completion of the gas conversion, replace the
gas type identification label located at:-
- The rear of the appliance, above the gas
connection.
- Beside the rating plate.
Commissioning
Before leaving the converted installation;
1. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
WARNING:
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES
2. Check the following functions in accordance
with the operating instructions specified in the
'Operation' section of this manual.

Light the Main Burners.

Check the Low Fire burner operation.

Check the High Fire burner operation.

Check the Griddle Burner operation (If Fitted).
Part 6
Gas Conversion
3. Ensure any adjustments done to components
NOTE:
If for some reason it is not possible to get the
appliance to operate correctly, shut off the gas
supply and contact the supplier of this appliance.
.
15
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG

Ensure that all the controls operate correctly.

Ensure that the operating pressure remains
correct.
that have the adjustments / settings sealed (e.g.
paint sealed) are re-sealed.