WV-PB5564E Alarm Board Dip Switch
Setting
1. Set switches (SW1) on the board to meet the alarm
input number as shown below.
BOARD
NO.
1
2
3
2. Set switches (SW4 - SW11) on the board to meet the
alarm input requirements. Initially, normally open
(NOR, OPEN) positions are selected at the factory.
NOR
CLOSE
NOR
OFF
OPEN
3. Confirm switchers (SW12) on the board are set to the following positions.
These switches are used only for factory test.
Always keep these switches in the "OFF" positions in the field.
ALARM
SW1 SETTING
INPUT NO.
1
2
1-64
OFF
1
2
65-128
OFF
SW4
1
2
3
4
5
6
7
8
Note
SW1
UNIT ADR
SW1
UNIT ADR
SW12
Switch No.
1
SW4
2
SW5
3
SW6
4
SW7
5
SW8
6
SW9
7
SW10
8
SW11
SW5
1
2
3
4
5
6
7
OFF
-42-
1
2
3
4
5
6
7
8
Alarm Input
Board No.1
Board No.2
1 - 8
65-72
9 - 16
73-80
17 - 24
81-88
25 - 32
89-96
33 - 40
97-104
41 - 48
105-112
49 - 56
113-120
57 - 64
121-128
8
SW12