Download Print this page

Sanyo 12KHS32 Submittal Sheet

Indoor/outdoor wall mounted heat pump
Hide thumbs Also See for 12KHS32:

Advertisement

Quick Links

SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
12KHS32
KHS1232/CH1232
WALL MOUNTED HEAT PUMP
GENERAL DATA
POWER V/PH/HZ
Circuit Ampacity, Min. (A)
Fuse size, Max.
(A)
COMPRESSOR
No. used
R.L. Amps - L.R. Amps (A)
Crankcase Heater
OUTDOOR FAN - TYPE
Dia. (in.) - No. used
Type Drive - No. speeds
No. Poles – RPM
No. Motors – HP
CFM (High)
F.L. Amps. (A)
OUTDOOR COIL – TYPE
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR FAN – TYPE
Dia. & Length (in.) - No. used
No. speeds
No. Poles -RPM (High)
No. Motors - HP
CFM (HI/MED/LOW)
F.L. Amps (A)
INDOOR COIL - TYPE
Fin Type - Pipe type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Drain Connection Size (in.)
REFRIGERANT
Lbs. - R22 (O.D. Unit)
Control
Connection
Line Length, Max
(ft.)
Lift difference, Max (ft.)
Line Size - in. O.D. Discharge
Line Size - in. O.D. Suction
DIMENSIONS (in.)
H
Indoor Unit
-Uncrated 14-3/16 x 39
-Crated
18-1/32 x 42-17/32 x 10-23/32
Outdoor Unit -Uncrated 20- 7/8
-Crated
23-17/32 x 35-13/32 x 13-7/8
WEIGHT
INDOOR
Net
(lbs.)
29.8
Shipping (lbs.)
37.5
Shipping Volume(cu.ft.) 4.8
(AT 230V)
230-208/1/60
20
20
Rotary-Hermetic
1
5.5 - 34
20W
Propeller
15-3/4 - 1
Direct - 1
6 - 840
1 - 1/38
820
0.4
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Riffled
2 - 15.9
3.29
3/8
Cross - Flow
4 & 30 - 1
3 & Auto
4 -1,330
1 - 1/75
360/310/260
0.2
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 - 14.1
2.08
3/8
1 - 1/4
R22
2.51
Capillary Tube
Flare
65
23
1/4
1/2
x
W
x
D
x 7-13/16
x 29-17/32 x 11-1/32
OUTDOOR
92.6
99.2
6.7
AIRCONDITIONING PRODUCTS
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
COOLING
Total Capacity
(BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity
(BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
HEATING
Total Capacity
(BTU/H)
HSPF
Amps (A)
Power Inputs (W)
Back-up Strip Heater (KW)
Outdoor Sound Rating(bels)
FEATURE
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver (Horizontal)
(Vertical)
Power Failure Automatic Restart
Self Diagnosis
Heating/Cooling Automatic Changeover
OPTION
Refrigerant Line Set
Low Ambient Control
Fresh Air Intake
Central Remote ON-OFF Control
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removable Remo-con Bracket
OPERATING RANGE
Cooling
Indoor Air
Intake Temp.
Maximum
95 F DB/71 F WB
Minimum
67 F DB/57 F WB
Heating
Maximum
80 F DB/67 F WB
Minimum
- F DB/ - F WB
CERTIFICATION
SS12KHS32-1
11,700/11,500
7,930/7,630
3,770/3,870
10.010.0
3.3/3.2
5.5/5.9
1,210/1,180
13,000/12,700
6.8/6.8
5.1/5.4
1,170/1,120
1.50/1.23
7.0
Microprocessor
LCD Wireless type
IC Thermostat
ON/OFF, 24 hours
Built-In
Manual
Automatic
Built-In
Built-In
Built-In
AP1205BH
(15 ft)
AP1207BH
(20 ft)
AP1210BH
(30 ft)
N/A
N/A
Available
N/A
PLB182
Available
Available
Outdoor Air
Intake Temp.
115 F DB
67 F DB
75 F WB/65 F WB
17 F WB/15 F WB
12KHS32

Advertisement

loading

Summary of Contents for Sanyo 12KHS32

  • Page 1 SUBMITTAL SHEET SYSTEM AIRCONDITIONING PRODUCTS INDOOR/OUTDOOR 12KHS32 KHS1232/CH1232 WALL MOUNTED HEAT PUMP SS12KHS32-1 GENERAL DATA (AT 230V) PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V) POWER V/PH/HZ 230-208/1/60 COOLING Circuit Ampacity, Min. (A) Total Capacity (BTU/H) 11,700/11,500 Fuse size, Max. Sensible Capacity (BTU/H)
  • Page 2: Dimensional Data

    11-1/32 service valve Dimension: in. WARRANTY Full specific warranty rights, conditions, exclusions and obligations are specified in the SANYO products are warranted against defects in materials and workmanship for the warranty packed with each products. period below; LABOR PARTS Compressor...

This manual is also suitable for:

Khs1232Ch1232