4=
Drill two 1/8"(3 mm) holes that correspond to the bracket
holes of the determined mounting method. See below.
A
ii¸
I
I
I
I
I
Floor Mounting
B
Wall Mounting
A. #12 x 1%" screws
B. Anti-tip bracket
A
B
5=
A. #12 x 1%" screws
B. Anti-tip bracket
Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1%" screws provided.
Explosion Hazard
Use a new CSA international
approved
gas supply line.
install a shut-off valve.
Securely tighten
all gas connections.
If connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed
heating personnel,
authorized
gas company personnel, and
authorized
service personnel.
Failure to do so can result in death, explosion,
or fire.
Typical flexible
connection
1. Apply pipe-joint
compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 15/16" combination
wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
J
B
C
/
o
D
E
y Y"
,"
_
H
G
F
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have V2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F V," or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter

Advertisement