Technical Specifications

Unit Environment and Operating
Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure,
and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude (unpressurized)
*NOTE: Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency Range
Rated Input Current
System Heat Dissipation
Power Supply Fan
FEMP Standby Power Compliant
(<2W in S5 – Power Off)**
Power Consumption in ES Mode – Suspend
to RAM (S3) (Instantly Available PC)
Environmental and Mechanical Engineering
Support Center (EMESC) – Intranet Web Site
only
** Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake on LAN"
feature disabled in F10 Setup (default is "enabled").
Slim Tower
Non-operating: 5% to 95% (non-condensing at ambient)
Slim Tower
240 watt custom power supply – Active PFC 365 watt custom power supply – Active PFC
90 – 264 VAC
100 – 240 VAC
47 – 63 Hz
Typical 340 btu/hr
(86 kg-cal/hr)
Maximum 1260 btu/hr
(318 kg-cal/hr)
80mm variable speed
http://env-webserver.ccm.cpqcorp.net/EMESC/default.htm
DA - 12583 Worldwide — Version 15 — September 19, 2007
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
50/60 Hz
5A
YES
< 3W
HP Compaq dx7300 Business PC
Microtower
Microtower
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
6A
Typical 375 btu/hr
(95 kg-cal/hr)
Maximum 1916 btu/hr
(483 kg-cal/hr)
92mm variable speed
YES
< 3W