Download Print this page

Electrolux EI30EF55GSB Installation Instructions Manual page 3

30" freestanding
Hide thumbs Also See for EI30EF55GSB:

Advertisement

BEFORE
STARTING
Tools You Will Need
For leveling
legs and Anti-Tip
Bracket:
• Adjustable wrench or channel lock pliers
• 5/16" Nutdriver or Flat Head Screwdriver
• Electric Drill & 1/8" Diameter Drill Bit
(Masonry Drill Bit if installing in concrete)
For electrical
supply
connection:
• 1/4" & 3/8" Socket driver or Nutdriver
Additional
Materials
You Will Need:
• Power Supply Cord or
• Copper Electrical Wiring & Metal Conduit
(for hard wiring)
NORMAL
INSTALLATION
STEPS
1.
ANTI-TIP
BRACKET
INSTALLATION
INSTRUCTIONS
- IMPORTANT
SAFETY
WARNING
To reduce the risk of tipping of the range, the range must be
secured to the floor by properly installed Anti-Tip Bracket and
screws packed with the range. Failure to install the anti-tip bracket
will allow the range to tip over if excessive weight is placed on an
open door or if a child climbs upon it. Serious injury might result
from spilled hot liquids or from the range itself.
3/16"
pilot hole
1-3/4"
deep.
The screws
provided
may be used
in wood or concrete
material.
Use a 5/16"
nut-driver
or flat
head
screwdriver
to secure
the bracket
in place
(See Fig. 6).
lC.
Level
and
Position
Range
- Level range
by adjusting
the (4) leveling
legs with a wrench.
NOTE:
A minimum
clearance
of 1/8" is required
between
the bottom
of the range
and the leveling
leg to allow
room for the bracket.
Use a spirit
level
to check
your
adjustments.
Slide
range
back
into position
(See Fig. 7).
Visually
check
that rear leveling
leg is inserted
into and fully
secured
by the Anti-Tip
Bracket
by removing
lower panel or
storage
drawer.
For models
with a Warmer
Drawer
or broiler
compartment,
grasp
the top rear edge
of the range and carefully
attempt
to tilt it forward.
FASTEN
BRACKET
(w_u_Lo_ FLOO_ MOUNTING)
---_1
1<--1-1/4
" Max.
Leveling
Leg --
I
Floor Mount
) Bracket
Fig. 5
FASTEN
BRACKET
(_Loo_ MOUNTINGONLY)
--_1
14-- More
Than
Floor Mount
--
_
nti-Tip
Bracket
Fig. 6
If range is ever moved to a different
location,
the Anti-Tip
Bracket
must also be moved
and installed
with the range.
Instructions
are provided
for installation
in wood or cement
fastened
to either
the floor or wall.
When
installed
to the wall,
make sure that screws
completely
penetrate
dry wall and are
secured
in wood or metal.
When
fastening
to the floor or wall, be
sure that screws
do not penetrate
electrical
wiring
or plumbing.
la.
Locate
the
Bracket
using the Template
- (Bracket
may be located
on either the left or right side of the range.
Use
the information
below to locate the bracket
if template
is not
available).
Mark the floor or wall where
left or right side of the range
will be located.
If rear of range
is against
the wall or no
further
than 1-1/4" from wall
when installed,
you may use
the wall or floor mount
method.
If molding
is installed
Fig. 4
and does not allow the bracket
to fit flush against
the wall, remove
molding
or mount
bracket
to the floor.
For wall mount,
locate the
bracket
by placing
the back edge of the template
against
the rear
wall and the side edge of template
on the mark made
referencing
the side of the range (See Fig. 4). Place bracket
on top of
template
and mark
location
of the screw holes in wall.
If rear of
range is further
than 1-1/4" from the wall when installed,
attach
bracket
to the floor.
For floor
mount,
locate the bracket
by placing
back edge of the template
where
the rear of the range will be
located.
Mark the location
of the screw
holes, shown
in template.
lb, Drill Pilot Holes & Fasten Bracket - Drill a 118"pilot
hole where
screws
are to be located.
If bracket
is to be mounted
to the wall, drill pilot hole at an approximate
20 ° downward
angle
(See Fig. 5).
If bracket
is to be mounted
to masonry
or ceramic
floors,
drill a
Range Side/v
""
Fig. 7
2. ELECTRICAL
CONNECTION
REQUIREMENTS
- This
appliance
must be properly
installed
and grounded
by a qualified
technician
in accordance
with the National
Electrical
Code ANSll
NFPA No. 70 -- latest edition
-- and Local Electrical
Code
requirements.
This appliance
may be connected
by means
of "Permanent
Wiring"
or "Power
Supply
Cord Kit."
When
installing
Permanent
Wiring,
do not leave excess wire in
range compartment.
Excess
wire in the range compartment
may
not allow the Rear Access
Cover to be replaced
properly
and
could create
a potential
electrical
hazard
if wires become
pinched.
Connect
only as instructed
under "Permanent
Wire
Connections"
in Step 4c. When
using flexible
conduit
or range
cable use flex connector
or range cable strain relief (Fig. 1 1 ).
2a. Models
with
Factory
Connected
Power
Supply
Cord.
NOTE: Some
models
may have a factory
installed
three
(3) conductor
Power Supply
Cord.
Mobile home installations, new branch circuit installations
(1996NEC) or areas where Local Codes do not permit grounding
through neutral require a four (4) conductor power supply cord kit
rated at 125/250 volts minimum and marked for use with ranges.
See Range
Connection
Opening
Size Chart
(Figs.
9 & 10) for
cord kit ampere
rating information.
Terminals
on end of wires
must be either closed
loop or open-end
spade
lugs with upturned
ends.

Advertisement

loading

This manual is also suitable for:

Ew30ef65gscEw30ef65gsbEw30ef65gwaEi30ef55gbaEi30ef55gsaEw30ef65gsa ... Show all