Cabinet Construction; Provide An Adequate Gas Supply - Electrolux EW30GS65GB8 Installation Instructions Manual

30" gas slide in range with sealed top burners
Hide thumbs Also See for EW30GS65GB8:
Table of Contents

Advertisement

Available languages

Available languages

Cabinet
Construction
Provide
an adequate
Gas Supply
To eliminate the risk of cabinet burns and
fire, do not have cabinet storage space above the range.
If there is cabinet storage space above range, reduce
risk by installing a range hood that projects horizontally
a minimum of 5" (12.7 cm) beyond the bottom of the
cabinet.
Countertop
Preparation
The cooktop sides of the range fit over the cutout
edge of your countertop.
• If you have a square finish
(flat) countertop,
no
countertop
preparation is required. Cooktop sides lay
directly on edge of countertop.
• Formed front-edged
countertops
must have
molded edge shaved flat 3/4" (1.9 cm) from each
front corner of opening (Figure 2).
• Tile countertops
may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge
flattened (Figure 2).
When shipped from the factory, this unit is designed to
operate on 4"(10,16
cm) water column (1.0 kPa)
Natural gas manifold pressure. A convertible pressure
regulator is connected to the range manifold and MUST
be connected in series with the gas supply line. If LP/
Propane conversion kit has been used, follow
instructions provided with the kit for converting the
pressure regulator to LP/Propane use.
Care must be taken during installation of range not to
obstruct the flow of combustion and ventilation
air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14"(35,56
cm) of
water column pressure (3.5 kPa). The inlet pressure to
the regulator must be at least 1 " (.25 kPa) greater than
the regulator manifold pressure setting. Examples: If
regulator is set for natural gas 4"(10,16
cm) manifold
pressure, inlet pressure must be at least 5"(12.60 cm); if
regulator has been converted for LP/Propane gas
10"(25,4 cm) manifold pressure, inlet pressure must be
at least 11 "(27,9 cm).
Leak testing of the appliance shall be conducted
according to the instructions in step 4.
31,/2,, _ _
(81cm)
Formed or tile countertop
trimmed
%" (1,9 cm) back at
(1,9 cm}
front corners
of countertop
opening,
I
Figure 2
• If the existing
cutout
width
is greater
than
30-1/16"
(76,4 cm), reduce the 3A" (1.9 cm)
dimension.
• Countertop
must be level. Place a level on the
countertop, first side to side, then front to back. If the
countertop is not level, the range will not be level. The
oven must be level for satisfactory baking results.
Cooktop sides of range fit over edges of countertop
opening.
• For existing
cutout width
of 29" (73.7
cm) (Figure 3):
The gas supply line should be Y2" or si" I.D. (Interior
Diameter)
[ Seal
the openings
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed.
You must also clear
2 3116" (5.56 cm) of
material
from front
of countertop,
Formed or tile counterto
trimmed
11A'' (3.2 cm) back at
front corners
of countertop
opening,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents