Emectrica[ Connection
Power
Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical
connections.
Connect
neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect
remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Electrical
Connection
Options
1. Choose
electrical
connection
type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to steps 1-2 on
page 8 for power supply cord strain relief:
then steps 3-6 for 4-wire Power Supply
Cord Connection
section. Then, go to
Venting Requirements.
Power supply cord 3=wire receptacle
(NEMA Type 10=30R): Go to steps 1-2 on
page 8 for power supply cord strain relief:
then steps 3-5 for 3-wire Power Supply
Cord Connection
section.
Then go to Venting Requirements.
4-wire direct connection: Go to steps
1=2 on page 10 for direct wire strain re=
lief: then steps 3-8 for 4-wire Direct Wire
Connection
section. Then go to Venting
Requirements.
3-wire direct connection:
Go to steps
1-2 on page 10 for direct wire strain relief:
then steps 3-7 for 3-wire Direct Wire
Connection
section. Then go to Venting
Requirements.
NOTE:
If local codes do not permit connection of a
cabinet-ground
conductor to neutral wire, go to "Optional
3-wire Connection"
section. This connection may be
used with either a power supply cord or a direct wire
connection.
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical
connections.
Connect
neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect
remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical
connections.
Failure to do so can result in death, fire, or
electrical
shock.
2. Remove
terminal
block
cover
B
E C
F
Before you start, disconnect
power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor
screw
C. Center terminal block screw
D. Hold-down
screw
E. Neutral ground wire
E Hole below terminal block cover