Cisco Catalyst 2950 Getting Started Manual page 18

Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

Using the ratcheting torque screwdriver,
Step 4
torque each terminal block captive screw
(above the installed wire leads) to 4.5 lbf-in.
(72 ozf-in.).
Insert the terminal block plug in the terminal
Step 5
block header on the rear panel of the
Catalyst 2950G-24-EI-DC switch or on the
front panel of the Catalyst 2950ST-24
LRE 997 switch.
Move the circuit-breaker handle for the DC power source to the on position.
Step 6
You must connect the Catalyst 2950G-24-EI-DC or Catalyst 2950ST-24 LRE 997 switch
Caution
only to a DC-input power source that has an input supply voltage from –36 to –72 VDC.
If the supply voltage is not in this range, the switch might not operate properly or might
be damaged.
18
Return
Feed A
Negative
Return
Feed B
Negative
3 6 - 7 2 V
1 - 0 .5 A
A
B