Download Print this page

AEG 353 WK-m Instruction Book page 7

Hide thumbs Also See for 353 WK-m:

Advertisement

Burner cover/inner burner
ring/outer burner ring
Together with the inner burner ring the
outer burner ring forms a space where the
final mixture of gas and air takes place in
order to make the gas burn correctly.
Please note: It is consequently very
important that the inner burner ring/outer
burner ring is placed correctly, together
with the cover.
If the burner cover/rings are wrongly
placed the burner will operate incorrectly,
and the burner may be damaged within a
short space of time. It is also important,
that the inner air ring is placed correctly.
Ignition electrode (A)
The burner has been provided with an
ignition electrode. As long as the
operating knob is depressed, the
automatic ignition will ensure that a
spark is emitted between the ignition
electrode and the burner cover.
Thermo Sensor (B)
The gas unit features fully-secured gas
taps (thermo-fuse)
In case the flame goes out, the thermo
sensor automatically prevents gas
admission after a shorter time (Max. 90
seconds).
Note: Gas admission is always allowed
while the operation button is pressed -
See start-up procedure
Burner ring
Cover
Ignition electrode (A)
Burner
Thermo Sensor (B)
Main nozzle

Advertisement

loading