OpERATION
An overloaded DC circuit, excessive current draw by the battery,
or a wiring problem will trip the DC circuit protector (PUSH
button extends out). If this happens, wait a few minutes before
pushing in the circuit protector to resume operation. If the DC
circuit protector continues to go OFF, discontinue charging
and see your nearest authorised service centre.
Disonnecting the battery cables:
Disconnect the negative (-) battery cable from the
n
generator negative (-) terminal.
Disconnect the other end of the negative (-) battery cable
n
from the battery negative (-) terminal.
Disconnect the positive (+) battery cable from the
n
generator positive (+) terminal.
Connect the other end of the positive (+) battery cable to
n
the battery positive (+) terminal.
Reconnect the vehicle ground battery cable to the
n
battery negative (-) terminal.
STARTING THE ENGINE ( RECOIL )
Open the fuel cock.
n
Put the engine speed lever in the "RUN" position.
n
Pull the starter handle slowly until you feel resistance.
n
Slowly release starting handle.
n
Push the decompression lever down and release.
n
Pull the rope hard and fast.
n
Allow engine to warm up for 3 minutes before connecting
n
the load.
NOTE: This unit is equipped with a low oil pressure sensor
to protect the engine. If unit will not start, recheck the oil
level to ensure it is properly filled.
STARTING THE ENGINE ( ELECTRIC )
Open the fuel cock.
n
Put the engine speed lever in the "RUN" position.
n
Turn the key to "START" position and release.
n
Allow engine to warm up for 3 minutes before connecting
n
the load.
STOPPING THE ENGINE
Return engine speed lever to "STOP" position.
n
Turn key to "OFF" position (Electric start only).
n
Close the fuel cock.
n
English

mAINTENANCE

WARNING:
When servicing, use only identical RYOBI
replacement parts. Use of any other parts may
create a hazard or cause product damage.
Only the parts shown on the parts list are intended to be
repaired or replaced by the customer. All other parts should
be replaced at an authorised service centre.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it is
not exposed to dust, dirt, moisture, or corrosive vapors. Do not
allow the cooling air slots in the generator to become clogged
with foreign material such as leaves, snow, etc.
Do not use a garden hose to clean the generator. Water
entering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
n
and remove dirt and debris.
Clean air vents with low pressure air that does not
n
exceed 25 psi.
Wipe the exterior surfaces of the generator with a damp
n
cloth.
CHECKING/CLEANING AIR FILTER
For proper performance and long life, keep air filters clean.
Lift the latches located at the top and bottom of the air
n
filter cover. Remove the cover and set aside.
Remove the filter elements.
n
If the filter elements are dirty, clean with warm, soapy
n
water. Rinse and let dry.
Apply a light coat of engine oil to the elements, then
n
squeeze it out.
Replace the elements in the air filter unit.
n
Replace the air filter cover and close latches to secure.
n
NOTE: Do not run the generator without the air filter.
Rapid engine wear will result.
CHANGING ENGINE OIL
Remove the oil cap/dipstick.
n
Place a container underneath the oil drainage bolt to
n
collect used oil as it drains.
Unscrew the oil drainage bolt and remove.
n
Allow oil to drain completely.
n
Reinstall the oil drainage bolt and tighten securely.
n
Refill with oil following the instructions in the Checking/
n
Adding Oil section.
Reinstall the oil cap/dipstick.
n
10