  • Page 1 DM 8600 Cooker Hood Operating and Installation Instructions...
  • Page 2: Table Of Contents

    Contents Safety warnings ................3 For the user ..................3 For the installer ................... 4 Description of the Appliance ............6 Extraction version ................6 Recirculation Version ................6 Control Panel ..................7 Grease and charcoal filter maintenance indicator ....... 8 Maintenance and Care ..............
  • Page 3: Safety Warnings

    Safety warnings For the user • The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. • Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.
  • Page 4: For The Installer

    For the installer • When used as an extractor unit, the hood must be fitted with a 150mm diameter duct. • When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces: electric cookers 500 mm...
  • Page 5 - short and straight outlet ducting - keep bends in outlet ducting to a minimum - never install the ducts with an acute angle, they must always follow a gentle curve. - keep the duct as large as possible (preferably the same diameter as the outlet hole).
  • Page 6: Description Of The Appliance

    Description of the Appliance • The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. • The hood is supplied as an extractor unit and can also be used with a recirculation version by fitting a charcoal filter. Extraction version •...
  • Page 7: Control Panel

    Control Panel • Best results are obtained by using a low speed for normal conditions and a high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking, you will then get an under pressure in the kitchen. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared.
  • Page 8: Grease And Charcoal Filter Maintenance Indicator

    Grease and charcoal filter maintenance indicator This hood is fitted with a device that indicates when it is necessary to clean the grease filter or the charcoal filter (if the hood is used in the recirculation version with a charcoal filter). On delivery, the hood is not supplied with a charcoal filter, so the saturation indicator will be disabled.
  • Page 9: Maintenance And Care

    Maintenance and Care • The hood must always be disconnected from the electricity supply before beginning any maintenance work. Cleaning the hood • Clean the outside of the hood using a damp cloth and a mild deter- gent. • Never use corrosive, abrasive or flammable cleaning products. •...
  • Page 10: Charcoal Filter

    Charcoal filter • The charcoal filter should only be used if you want to use the hood in the recirculation function. • To do this you will need an original charcoal filter (available from your local Service Centre). • Cleaning/replacing the charcoal filter Unlike other charcoal filters, the LONGLIFE charcoal filter can be cleaned and reactivated.
  • Page 11: Changing The Light Bulb

    Warning • Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. • The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
  • Page 12: Something Not Working

    Something Not Working If your appliance fails to work properly please carry out the following checks. Symptom Solution The cooker hood Check that: The hood is connected to will not start... the electricity supply. Check that a fan speed has been selected The cooker hood Check that: The fan speed is set...
  • Page 13: Technical Specifications

    Technical Specifications Dimensions* - extraction version (in cm): Height 66-112 Dimensions* - recirculation version (in cm): Height 75,5-122 Maximum absorbed power (W): 210 Motor (W): Lighting (W): 2x20 Length of the cable (cm): 150cm Electrical connection (V): 220-240 * Width and depth depend on the vapour screen which is installed with the cooker hood, see page 17 Mounting accessories included 1 allen spanner (for TORX screws).
  • Page 14: Wall Unit Mounting

    Wall unit mounting - Fig. 6-7 First decide which functioning mode is better for you. If you decide to use the hood in extraction mode we suggest you position the upper section of the chimney so that the oulet slots are not visible once installation is completed, however if is decided to use the hood in rrecirculation mode BE SURE that the side with slots is up (see also A-B-C sequence on on Fig.
  • Page 15 • Mark the wall with a centre line, this will aid mounting procedure (1), position the template so that the mid line printed on the template matches with the centre line previously signed, the lower side of the template corresponds to the lower side of the hood once mounted (2).
  • Page 16 Fig. 7...
  • Page 17 Special accessories/Vapour screen SM 8090 E-Nr. 942 121 998 SM 8091 E-Nr. 942 121 999 SM 8092 E-Nr. 942 122 000 SM 8093 E-Nr. 942 122 001 SM 8010 E-Nr. 942 122 006 BM 8005 E-Nr. 942 122 009 SM 8085 (88cm) - E-Nr. 942 122 007 SM 8065 (60 cm) - E-Nr.
  • Page 20 From the Electrolux Group. The world´s No.1 choice. The Electrolux Group is the world´s largest producer of powered appliances for kitchen, cleaning and outdoor use. More than 55 million Electrolux Group products (such as refrigerators, cookers, washing machines,vacuum cleaners, chain saws and lawn mowers) are sold each year to a value of approx.