Water Line Connection; Drain Line Connection - GE 400 Series Maintenance Manual

Water conditioning control system
Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

6. Do not install unit near acid or acid fumes.
7. The use of resin cleaners in an unvented enclosure is not recommended.

Water Line Connection

The installation of a bypass valve system is recommended to provide for occasions
when the water conditioner must be bypassed for hard water or for servicing.
The most common bypass systems are the Autotrol
(Figure 4) and plumbed-in globe valves (Figure 5). Though both are similar in function,
the 256 Autotrol bypass offers simplicity and ease of operation.

Drain Line Connection

1. Ideally located, the unit will be above and not more than 20 feet (6.1 m) from the
drain. For such installations, use an appropriate adapter fitting (not supplied), to
connect 1/2-inch (1.3-cm) plastic tubing to the drain line connection of the control
valve.
Not in Bypass
Figure 4 Autotrol Series 256 Bypass Valve
Not in Bypass
Water
Conditioner
Figure 5 Typical Globe Valve Bypass System
®
Series 256 bypass valve
In Bypass
Water
Conditioner