GE Spacemaker WSKS2060T Dimension Manual page 2

Stationary washer and dryer with stack rack

Advertisement

GE Appliances
WSKS2060T/DSKS433ET—Spacemaker
Best Performance
Maximum Length of 4"
Dia. Rigid Metal Duct
A
Exhaust Hood Type
4
B
Cat. No.
WX8X59
Number
2-1/2
(Preferred)
of
A
90°
Domestic
4" Opening
Dryer Models
Turns
0
46 ft.
®
Spacemaker
Models
1
38 ft.
DSKS433ET
2
31 ft.
WSM2780T
3
24 ft.
0
43 ft.
®
Spacemaker
Model
1
33 ft.
DSKP233ET
3
23 ft.
0
56 ft.
1
46 ft.
®
Spacemaker
Model
2
34 ft.
WSM2700T
3
32 ft.
®
Spacemaker
Models
0
43 ft.
WSM2420T
1
33 ft.
WSM2480T
2
23 ft.
Revised 11/98
®
Stationary Washer and Dryer with Stack Rack DSR24RT
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If "all rigid metal" duct cannot be used, then "flexible
Maximum Length of 4"
all metal" venting can be used, but it will reduce the maximum recommended duct length.
Dia. Rigid Metal Duct
Exhaust Length Calculation:
Exhaust Hood Type
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible
Cat. No.
ducts are less than for rigid duct.
WX8X59
B
B
(Preferred)
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated
2-1/2"
2-1/2"
A
as a 90° elbow.
Opening
Opening
4" Opening
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room.
37 ft.
30 ft.
24 ft.
Gas dryers or any dryer located in a closet must be exhausted to the outside.
30 ft.
25 ft.
20 ft.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the
22 ft.
20 ft.
14 ft.
accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a
15 ft.
16 ft.
10 ft.
kitchen exhaust, since the combination of lint and grease could create a fire hazard.
36 ft.
30 ft.
24 ft.
26 ft.
24 ft.
18 ft.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least
12" above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable
16 ft.
16 ft.
10 ft.
provided they are equivalent to a 4" opening dampered wall cap.
42 ft.
30 ft.
22 ft.
36 ft.
22 ft.
14 ft.
Special Installation Requirements
28 ft.
16 ft.
10 ft.
Alcove or Closet Installation:
18 ft.
10 ft.
5 ft.
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
36 ft.
30 ft.
24 ft.
• The dryer MUST be exhausted to the outside.
26 ft.
24 ft.
18 ft.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
16 ft.
16 ft.
10 ft.
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet
contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line.
• No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
•Minimum clearances to combustible surfaces
0" either side
3" front and rear
0" both sides
3" rear
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
R

Advertisement

loading

This manual is also suitable for:

Spacemaker dsks433etSpacemaker dsr24rt