Installation Instructions

Mounting
The amplifier should be mounted vertically with the cable input underneath, to secure
best possible operating temperature conditions. Use a 4 mm Allen key to tighten the
screw in the lid to 5 Nm.
The pin length of the PG 11 cable connector at input and output is shown on the
cover plate of the amplifier. If needed, trim the connector with wire cutters.
Please Notice
This product can only be setup with a handheld terminal type A91200.11 or with a
handheld terminal type A91200.10 containing the necessary driver for the EGC
amplifier. New drivers can be installed by means of download kit A91210.10.
Plug-in Units
The following plug-in units are necessary.
Input splitter. Link type 74089 is applied if the loop port is not used.
Output splitter. If an asymmetric splitter (bridger) is used, the largest
attenuation at the output 2 (OUT 2) is obtained. If only a signal at output 1
(OUT 1) is requested, link type 74069 is used.
Diplex filter. Two diplex filters type 75130 with the required split frequency.
Use two links type 74089 if the reverse path not is used.
Plug-in reverse equalizer type 74141 with the required filter frequency.
Determines the frequency range for the built-in active reverse path.
AUX plug-in field. In order to adjust the amplifiers to the cable, it may be
necessary to insert an equalizer type 74100-xxx at the input. Alternatively an
inverse equalizer type 74190-xx or attenuator type 77150-xx can be used.
If no equalization/attenuation is requested, insert 0 dB link type 74069.
OL-30194-01
Continued on next page
7