Troubleshooting Procedures - Maytag AKT3040 Series Service Manual

Updraft electric cooktops
Table of Contents

Advertisement

Troubleshooting Procedures

To avoid risk of electrical shock, personal injury or death, disconnect power to cooktop before servicing, unless
testing requires power.
Problems
Switch burns out immediately after
installation.
Element fails to heat; indicator light
glows.
Element too hot; no control of heat at
any setting.
Element too hot on HI setting only.
Erratic operation of surface elements.
Indicator light remains on when control
is turned OFF or does not light when
control is turned ON.
Element making a humming noise.
Runaway surface control.
Poor performance when unit is
installed.
Broken glass.
Glass − ceramic heater is wavy or
uneven.
Red spots or lines visible through
glass−ceramic heater panel.
Performance of surface element is
poor.
8
!
WARNING
Improper wiring installation Hot Wired to Neutral terminal.
Warranty is VOID.(SEE Installation Instructions.)
NOTE: Possible damage to glass.
1. Element is burned out.
2. Failed limit switch.
3. Failed infinite switch.
Failed infinite switch or limit has welded contacts.
Failed limit switch.
Loose or broken wiring.
Infinite switch or hot light switch failed:
NOTE: In case where light does not light, could be failed indicator
light. Possible inductance voltage, separate indicator light
wires running parallel with power supply wires.
Caused by a 60 Hz AC current passing through element winding.
Normal occurrence does not affect performance.
1. Failed infinite switch.
2. Improperly wired.
1. Knobs on surface controls indicating incorrect setting. (knob set
to HI control is actually set on LO.)
2. Improper wiring or switch installation.
Check for runaway surface control, faulty limit switch that could
have caused glass to break.
Manufacturing process gives glass − ceramic heater panel a slight
wave across surface.
This IS NOT a defect.
Glass−ceramic heater panels are slightly opaque. Element may
transfer a glow through a panel. This IS NOT a defect in the unit
and has no effect on performance.
1. See test procedures.
2. Make sure pans are flat on bottom.
16022159 Rev. 0
Solutions
©2003 Maytag Appliances Company

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents