Troubleshooting; Troubleshooting Guide; Troubleshooting Tests - Maytag MED / GD 9700S Technical Education

Front-loading gas and electric dryers
Table of Contents

Advertisement

TROUBLESHOOTING GUIDE

WILL NOT POWER UP.
( No response when Control
On button is pressed.)
WILL NOT START CYCLE
WHEN START BUTTON IS
PRESSED.
WILL NOT SHUT OFF
WHEN EXPECTED.
CONTROL WILL NOT
ACCEPT SELECTIONS.
WILL NOT HEAT.
HEATS IN AIR CYCLE.
SHUTS OFF BEFORE
CLOTHES ARE DRY.

TROUBLESHOOTING TESTS

NOTE: These checks are done with the dryer
unplugged or disconnected from power.
TEST #1: SUPPLY CONNECTIONS
This test assumes that proper voltage is
present at the outlet.
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the top right
corner of the back of the dryer.

TROUBLESHOOTING

PROBLEM
NOTE: Possible Cause/Tests MUST be performed
in the sequence shown for each problem.
1. Supply connection. See TEST #1.
2. Check harness connections.
3. Console electronics and housing. See TEST #5.
1. If number display flashes, check to be sure the
door is completely shut, and press and hold
down HOLD TO START for about 1 second.
2. See TEST #2.
3. See TEST #6.
1. Check OFF/Pause button. See TEST #5.
2. Console electronics and housing. See TEST #5.
3. Moisture Sensor. See TEST #4.
Console electronics and housing. See TEST #5.
1. Heater. See TEST #3.
2. Check harness connections.
3. Check installation.
Thermistor. See TEST #3a.
Moisture Sensor. See TEST #4.
Remove Screw
Cover Plate
POSSIBLE CAUSE / TEST
3.
Gas Dryers Only:
a) Check that the power cord is firmly con-
nected to the dryer's wire harness.
b) Access the electronic control board
without disconnecting any wiring to the
control board.
Power Cord-To-Wire Harness
Connection For Gas Dryer
6-4
Wire Harness
Power Cord

Hide quick links: