Installation
Instructions
NOTE:
If you need to install ducts, note that the total
duct lengtb of 3¼" x 10" rectangular
or 6" diameter
round duct should not exceed
140 equivalent feet.
Outside ventilation
requires
a HOOD EXHAUST DUCT.
Read tile following carefully.
NOTE:
It is important
tbat venting be installed
using
the most direct route and with as few elbows as possible.
This ensures clear venting of exhaust
and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
Exhaust connection:
The hood exhaust has been designed
to mate witb
a standard
3¼" x 10" rectangular
duct.
If a round duct is required,
a rectangular-to-round
transition
adaptor
must be used. Do not use less than
a 6" diameter duct.
Maximum
duct length:
For satisfhctory air movement,
the total duct length of"
3¼" x 10" rectangular
or 6" diameter
round duct should
not exceed 140 equivalent feet.
Elbows,
transitions,
wall and roof caps, etc.,
present additional
resistance
to airflow and are equivalent
to a section of straight duct which is longer than their
actual physical size. When calculating
the total duct
lengtb, add tbe equivalent
lengtbs of all transitions
and
adaptors
plus tbe length of all straight duct sections.
The chart below shows you how to calculate total
equivalent
ductwork length using the approximate
feet
of equivalent
lengtb of some typical ducts.
EQUIVALENT
NUMBER
EQUIVALENT
DUCT PIECES
LENGTH
x
USED
=
LENGTH
Rectangular_to-Round
5 Ft.
x
(
)
Ft.
TransitionAdaptor*
Wall Cap
40 Ft.
x
(
)
Ft.
(i)_
9O°EIbow
lOFt.
x
(
)
Ft.
(_
45° Elbow
5 Ft.
x
(
)
Ft.
90° Elbow
25 Ft.
x
(
)
Ft.
45° Elbow
5 Ft.
x
(
)
Ft.
RoofCap
24 Ft.
x
(
)
Ft.
Straight Duct6" Roundor
1 Ft.
x
(
)
Ft.
3¼" x 10" Rectangular
Total Ductwork
=
Ft.
* IMPORTANT:
if a iectangtflm_to-round
transition
Equiwflent
lengths
of duct
pieces
are based
on actual
tests
and
adaptor is used, the bottom cornm_ of the damper
reflect requirements
for good venting performance
with any
_'iU ha_e to be cut to fit, t_sing
the tin snips, in
_ent
hood.
order
to aUo_ fi'ee inovement
of the damper.
5