(3)
Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation.
Mode of
Operation
Model
MPA
3017AT
Spin up
Idle (Ready) (*3)
0.120 A
R/W (On Track)
0.130 A
(*4)
Seek (Random)
0.370 A
(*5)
Standby
Sleep
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any
commands.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical
track.
*5 Seek mode is defined as continuous random seek operations with minimum controller delay.
1 - 6
Table 1.3

Current and power dissipation

Typical RMS current (*1)
+12 V
MPA
MPA
3026AT
3043AT
MPA
MPA
3035AT
3052AT
1.3 A
1.5 A peak
0.6 A peak
0.155 A
0.185 A
0.160 A
0.190 A
0.380 A
0.425 A
0.01 A
0.01 A
C141-E034-02EN
Typical Power (*2)
+5 V
All Models
MPA
3017AT
0.520 A
0.443 A
3.66 watts
0.620 A
4.66 watts
0.520 A
7.04 watts
0.400 A
0.350 A
MPA
MPA
3026AT
3043AT
MPA
MPA
3035AT
3052AT
18.2 watts
4.08 watts
4.44 watts
5.02 watts
5.38 watts
7.16 watts
7.70 watts
2.12 watts
1.87 watts