CAUTION
Do NOT operate cooling if outdoor temperature
is below 50 F [10 C]. Refer to manufacturer's
recommendations.
First press—cooling system and SYSTEM LED on.
Second press—cooling system and SYSTEM LED off.
b
A four-digit code number will appear when the key is
released. The four digits of the code represent the
following options:
First
Digit
0
2
4
6
Second
Digit
Model
0
T8631R
1
T8631R
2
T8631A
3
T8631A
4
T8631R
5
T8631R
6
T8631A
7
T8631A
a
Adaptive Intelligent Recovery™
This equipment is a Class B digital apparatus which complies with Canadian Radio Interference Regulations, CRC c. 1374.
T8631A
T8631R
CPH
CPH
1
3
3
3
9
6
6
6
Recovery
Degrees
Type
F
A.I.R.
C
A.I.R.
F
Conventional
C
Conventional
F
A.I.R.
C
A.I.R.
F
A.I.R.
C
A.I.R.
Third
c
If the system switch is in HEAT, the following se-
quence will occur:
Fourth Digit: Not used.
!
CAUTION
Do NOT operate heating until heat pump warmup
procedure is followed. Refer to manufacturer's
recommendations.
T8631A:
First press—1st stage heating and SYSTEM LED on.
Second press—heating and SYSTEM LED off.
T8631R:
a
First press—1st stage heating and SYSTEM LED on.
a
Second press—2nd stage heating also on.
Third press—2nd stage heating off.
Fourth press—1st stage heating and SYSTEM LED off.
(If system switch is in EM. HT., operation is as above,
a
except 1st stage heating is locked out.)
a
a
REFER TO OWNER'S MANUAL FOR PROGRAM-
a
MING INSTRUCTIONS AND HOMEOWNER
TROUBLESHOOTING.
7
System Switch
Digit
0
1
2
4
Position
OFF
COOL
HEAT
EM.HT.
69-0689—2

Advertisement

loading

This manual is also suitable for:

T8631rChronotherm iii t8631aChronotherm iii t8631r